Your browser doesn't support javascript.
loading
Spatial attention U-Net model with Harris hawks optimization for retinal blood vessel and optic disc segmentation in fundus images.
Kumar, Puranam Revanth; Shilpa, B; Jha, Rajesh Kumar; Chellibouina, Veni Sree.
Affiliation
  • Kumar PR; Department of Artificial Intelligence and Machine Learning, School of Engineering, Malla Reddy University, Hyderabad, India. revanth123451.rk@gmail.com.
  • Shilpa B; Department of Computer Science and Engineering, AVN Institute of Engineering and Technology, Hyderabad, India.
  • Jha RK; Department of Electronics and Communication Engineering, Faculty of Science and Technology (IcfaiTech), ICFAI Foundation for Higher Education, Hyderabad, India.
  • Chellibouina VS; Department of Ophthalmology, Pushpagiri Vitreo Retina Institute, Hyderabad, India.
Int Ophthalmol ; 44(1): 359, 2024 Aug 29.
Article in En | MEDLINE | ID: mdl-39207645
ABSTRACT

BACKGROUND:

The state of the human eye's blood vessels is a crucial aspect in the diagnosis of ophthalmological illnesses. For many computer-aided diagnostic systems, precise retinal vessel segmentation is an essential job. However, it remains a difficult task due to the intricate vascular system of the eye. Although many different vascular segmentation techniques have already been presented, additional study is still required to address the problem of inadequate segmentation of thin and tiny vessels.

METHODS:

In this work, we introduce the Spatial Attention U-Net (SAU-Net) model with harris hawks' optimization (HHO), a lightweight network that can be applied as a data augmentation technique to improve the efficiency of the existing annotated samples without the need of thousands of training instances for Retinal Blood Vessel and Optic Disc Segmentation. The SAU-Net-HHO implementation uses a spatially inferred attention map multiplied by the input feature map for adaptive feature enhancement. U-Net convolutional blocks have been replaced with structured dropout blocks in the proposed network to prevent overfitting. Data from both vascular extraction (DRIVE) and structured analysis of the retina (STARE) are used to evaluate SAU-Net-HHO performance.

RESULTS:

The results show that the proposed SAU-Net-HHO performs well on both datasets. Analysing the obtained results, an average of 98.5% accuracy and Specificity 96.7% was achieved for DRIVE dataset and 97.8% accuracy and specificity 94.5% for STARE dataset. The proposed method yields numerical results with average values that are on par with those of state-of-the-art methods.

CONCLUSION:

Visual inspection has revealed that the suggested method can segment thin and tiny vessels with greater accuracy than previous methods. It also demonstrates its potential for real-life clinical application.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Optic Disk / Retinal Vessels / Fundus Oculi Limits: Humans Language: En Journal: Int Ophthalmol Year: 2024 Document type: Article Affiliation country: India Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Optic Disk / Retinal Vessels / Fundus Oculi Limits: Humans Language: En Journal: Int Ophthalmol Year: 2024 Document type: Article Affiliation country: India Country of publication: Netherlands