Your browser doesn't support javascript.
loading
Mechanical investigation of a Tandem embolization-visualization system for minimally invasive procedures.
Chen, Peng; Varghese P J, George; Zhao, Keren; Hu, Jingjie.
Affiliation
  • Chen P; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA, 27695.
  • Varghese P J G; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA, 27695.
  • Zhao K; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA, 27695.
  • Hu J; Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC, USA, 27695. Electronic address: jhu35@ncsu.edu.
J Mech Behav Biomed Mater ; 160: 106739, 2024 Sep 11.
Article in En | MEDLINE | ID: mdl-39276435
ABSTRACT
Transcatheter arterial embolization is a minimally invasive intervention process in which the blood supply to a tumor or an abnormal area of tissue is blocked. One of the most commonly used embolic agents in clinics is microsphere (MS). In order to understand the flow behavior of microspheres in arteries, it is essential to study their mechanical properties systematically. In this work, calcium-alginate MSs with varying calcium concentrations were synthesized using a coaxial airflow method. Indocyanine green (ICG) was added as a fluorescent dye. The effect of ICG concentration change on microspheres was investigated by studying morphology, imageability, rheology, and swelling behavior. Then the effect of calcium chloride concentration change on microspheres was studied by conducting rheological tests, atomic force microscopy tests, hemolysis assay, and thrombogenicity assay. Results showed that microspheres with higher ICG concentrations have longer lasting fluorescence and lower storage modulus (G'). Higher concentrations of calcium chloride led to higher G', while the local Young's modulus obtained by AFM test was not significantly affected. The MSs with and without ICG showed good hemocompatibility and thrombogenicity.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Mech Behav Biomed Mater Journal subject: ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Mech Behav Biomed Mater Journal subject: ENGENHARIA BIOMEDICA Year: 2024 Document type: Article Country of publication: Netherlands