Your browser doesn't support javascript.
loading
High throughput detection of veterinary drug residues in chicken and eggs.
Li, Feng; Lv, Huijie; Zhu, Feng; Zhang, Qiuping; Xu, Qian; Ji, Wenliang.
Affiliation
  • Li F; Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China.
  • Lv H; Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China.
  • Zhu F; Jiangsu Provincial Center for Disease Control and Prevention, Nanjing 210009, China.
  • Zhang Q; Suzhou Municipal Center for Disease Prevention and Control, Suzhou 215004, China.
  • Xu Q; Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China. Electronic address: q-xu@seu.edu.cn.
  • Ji W; Jiangsu Provincial Center for Disease Control and Prevention, Nanjing 210009, China. Electronic address: jwl320911@163.com.
Food Chem ; 463(Pt 2): 141267, 2024 Sep 12.
Article in En | MEDLINE | ID: mdl-39288463
ABSTRACT
Co-extraction of multiple types of target substances is the key to achieve high throughput detection. In this work, PDA@MOF-808/PAN NFsM was prepared by co-modified polyacrylonitrile nanofiber membrane (PAN NFsM) with polydopamine (PDA) and metal-organic framework-808 (MOF-808), and its potential as a solid-phase extraction (SPE) adsorbent was investigated by using the most typical nine veterinary drug residues in eggs and chicken as model target substances. The results show that PDA@MOF-808/PAN NFsM could effectively co-extract all the target substances (adsorption efficiency ranged from 81.46 % to 96.78 %), and had good capability of sample matrix purification (matrix effect was lower than -15.26 %), so a new SPE method has been established. Combined with UPLC-MS/MS, the detection limits were 0.3 to 3.1 µg/kg, the recoveries were between 71.02 % and 106.48 %, and the relative standard deviations were lower than 12.03 %, indicating that the method has considerable good sensitivity, accuracy and precision.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Food Chem Year: 2024 Document type: Article Affiliation country: China Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Food Chem Year: 2024 Document type: Article Affiliation country: China Country of publication: United kingdom