Ontario accelerator dose intercomparison study.
J Can Assoc Radiol
; 32(1): 49-53, 1981 Mar.
Article
in En
| MEDLINE
| ID: mdl-7217168
An ionometric dose intercomparison has been carried out on eight accelertors, with maximum photon energies from 6 to 32 meV, at five radiotherapy centres in Ontario. The ratio of the dose based on the clinically-employed rad/monitor unit to the dose measured by the committee representative had a mean value of 0.994, with a range of 7.3% and a coefficient of variation of 2.5%. The ratio of the dose measured by the institution's physicist to the dose measured by the committee representative had a mean value of 1.000 with a range of 6.9% and a coefficient of variation of 2.3%. Eight recommendations regarding dose calibration procedures are presented.
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Radiotherapy Dosage
Type of study:
Guideline
Limits:
Humans
Country/Region as subject:
America do norte
Language:
En
Journal:
J Can Assoc Radiol
Year:
1981
Document type:
Article
Country of publication:
Canada