Biomechanical testing of the spine. Load-controlled versus displacement-controlled analysis.
Spine (Phila Pa 1976)
; 20(21): 2354-7, 1995 Nov 01.
Article
in En
| MEDLINE
| ID: mdl-8553127
Mechanical testing of the spine can be carried out in either a load-controlled or a displacement-controlled manner. Each method requires certain assumptions and offers different advantages. Dr. W. Thomas Edwards believes that displacement-controlled testing most accurately reflects the in vivo environment, while Drs. Vijay Goel, David Wilder, and Malcolm Pope support the use of the load-controlled method as most logical and easily standardized.
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Spinal Diseases
/
Spine
Limits:
Humans
Language:
En
Journal:
Spine (Phila Pa 1976)
Year:
1995
Document type:
Article
Affiliation country:
United States
Country of publication:
United States