Your browser doesn't support javascript.
loading
Short- and long-term performance of a tripolar down-sized single lead for implantable cardioverter defibrillator treatment: a randomized prospective European multicenter study. European Endotak DSP Investigator Group.
Sandstedt, B; Kennergren, C; Schaumann, A; Herse, B; Neuzner, J.
Affiliation
  • Sandstedt B; Division of Cardiology, Sahlgrenska University Hospital, Göteborg Sweden.
Pacing Clin Electrophysiol ; 21(11 Pt 1): 2087-94, 1998 Nov.
Article in En | MEDLINE | ID: mdl-9826861
ABSTRACT
A new, thinner (10 Fr) and more flexible, single-pass transvenous endocardial ICD lead, Endotak DSP, was compared with a conventional lead, Endotak C, as a control in a prospective randomized multicenter study in combination with a nonactive can ICD. A total of 123 patients were enrolled, 55 of whom received a down-sized DSP lead. Lead-alone configuration was successfully implanted in 95% of the DSP patients vs 88% in the control group. The mean defibrillation threshold (DFT) was determined by means of a step-down protocol, and was identical in the two groups, 10.5 +/- 4.8 J in the DSP group versus 10.5 +/- 4.8 J in the control group. At implantation, the DSP mean pacing threshold was lower, 0.51 +/- 0.18 V versus 0.62 +/- 0.35 V (p < 0.05) in the control group, and the mean pacing impedance higher, 594 +/- 110 omega vs 523 +/- 135 omega (p < 0.05). During the follow-up period, the statistically significant difference in thresholds disappeared, while the difference in impedance remained. Tachyarrhythmia treatment by shock or antitachycardia pacing (ATP) was delivered in 53% and 41%, respectively, of the patients with a 100% success rate. In the DSP group, all 28 episodes of polymorphic ventricular tachycardia or ventricular fibrillation were converted by the first shock as compared to 57 of 69 episodes (83%) in the control group (p < 0.05). Monomorphic ventricular tachycardias were terminated by ATP alone in 96% versus 94%. Lead related problems were minor and observed in 5% and 7%, respectively. In summary, both leads were safe and efficacious in the detection and treatment of ventricular tachyarrhythmias. There were no differences between the DSP and control groups regarding short- or long-term lead related complications.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Defibrillators, Implantable / Electrodes, Implanted Type of study: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Pacing Clin Electrophysiol Year: 1998 Document type: Article
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Defibrillators, Implantable / Electrodes, Implanted Type of study: Clinical_trials / Guideline / Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Pacing Clin Electrophysiol Year: 1998 Document type: Article