Your browser doesn't support javascript.
loading
Iatrogenic Aortic Dissection Following Mitral Valve Replacement: A case report / 대한마취과학회지
Article in Ko | WPRIM | ID: wpr-193256
Responsible library: WPRO
ABSTRACT
Iatrogenic aortic dissection (IAD) is a life-threatening complication that can occur during open heart surgery, therefore IAD requires early diagnosis and prompt management. We describe here a case of IAD that occurred during mitral valve replacement. The transesophageal echocardiography (TEE) evaluation revealed features indicative of acute aortic dissection and the tear was successfully repaired by interposition of a graft.
Subject(s)
Key words
Full text: 1 Database: WPRIM Main subject: Thoracic Surgery / Echocardiography, Transesophageal / Transplants / Early Diagnosis / Mitral Valve Type of study: Diagnostic_studies / Screening_studies Language: Ko Journal: Korean Journal of Anesthesiology Year: 2007 Document type: Article
Full text: 1 Database: WPRIM Main subject: Thoracic Surgery / Echocardiography, Transesophageal / Transplants / Early Diagnosis / Mitral Valve Type of study: Diagnostic_studies / Screening_studies Language: Ko Journal: Korean Journal of Anesthesiology Year: 2007 Document type: Article