Your browser doesn't support javascript.
loading
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture
Article in Ko | WPRIM | ID: wpr-221489
Responsible library: WPRO
ABSTRACT

PURPOSE:

To evaluate the clinical and radiological results of minimally invasive plate, osteosynthesis, using either a locking compression plate-distal tibia (LCP-DT) or Zimmer periarticular locking plate (ZPLP) for distal tibia fractures. MATERIALS AND

METHODS:

Fifty one patients (51 cases), who underwent minimally invasive osteosynthesis using locking compression plate for distal tibia fractures between October 2008 and August 2011, were followed for more than six months. Eighteen patients were treated with LCP-DT and 33 patients with ZPLP. Time to bony union and anatomic alignment were evaluated radiologically. Clinically, American Orthopedic Foot & Ankle Society ankle-hindfoot scales (AOFAS score) and range of ankle motion were assessed and compared between two groups.

RESULTS:

All patients achieved bony union at an average of 18 weeks on LCP-DT group and 16weeks on ZPLP group. The average American Orthopedic Foot & Ankle Society ankle-hindfoot scales was 83.3 points on the LCP-DT group, 84.6 points on the ZPLP group, and range of ankle motion averaged at 45 degrees, 48 degrees, respectively.

CONCLUSION:

Both types of locking compression plates were effective when performing minimally invasive osteosynthesis for distal tibia fractures.
Subject(s)
Key words
Full text: 1 Database: WPRIM Main subject: Orthopedics / Tibia / Weights and Measures / Foot / Ankle Limits: Animals / Humans Language: Ko Journal: Journal of the Korean Fracture Society Year: 2013 Document type: Article
Full text: 1 Database: WPRIM Main subject: Orthopedics / Tibia / Weights and Measures / Foot / Ankle Limits: Animals / Humans Language: Ko Journal: Journal of the Korean Fracture Society Year: 2013 Document type: Article