Objective To introduce the application of computer aided technology in the treatment of pelvic malunion and observe the effect of this technique on the operation.Methods Data of 9 consecutive patients with pelvic malunion who were enrolled in our hospital from January 2009 to December 2012 were retrospectively observed.There were 4 patients who had undergone surgery with computer aided technology,including 3 men and 1 woman with an average age of 34 years (computer aided technology,CAT) group.According to the Tile classification,4 cases were all type C.There were 1 case with open pelvic fractures,2 associated with the craniocerebral injury,2 associated with the thoracic injury and 2 associated with the abdomen trauma.There were 5 patients who had undergone surgery without computer aided technology,including 3 men and 2 women with an average age of 32.6 years (conventional group).According to the Tile classification,4 cases were all type C.There were 1 case with open pelvic fractures,2 associated with the craniocerebral injury,3 associated with the thoracic injury and 1 associated with the abdomen trauma.The Majeed score,the visual analogue score (VAS),operation time,blood loss,blood transfusion,intraoperative fluoroscopy,degree of improvement in lower limb length,iatrogenic injury and the complication were all recorded respectively.Results For the CAT group,the operation time was 195-230 min,the blood loss was 800-1 6 00 ml,the blood transfusion was 6-16 U,intraoperative fluoroscopy was 6-11 times and the degree of improvement in lower limb length was 2-3 cm.The Majeed score in the final follow-up was 78-90 points,including 3 excellent cases and 1 good.The VAS after surgery was 0-4 points.For the conventional group,the operation time was 210-330 min,the blood loss was 600-4 500 ml,the blood transfusion was 6-28 U,intraoperative fluoroscopy was 7-18 times and the degree of improvement in lower limb length was 1-3 cm.The Majeed score in the final follow-up was 79-89 points,including 3 excellent cases and 2 good.The VAS after surgery was 1-4 points.Conclusion Surgeons can make full preoperative planning by the computer aided technology before the operation.This technology which reduces the operation time can make the operation more accurately,effectively and safely.
Full text:
1
Database:
WPRIM
Language:
Zh
Journal:
Chinese Journal of Orthopaedics
Year:
2015
Document type:
Article