Your browser doesn't support javascript.
loading
Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes
Yonsei Medical Journal ; : 1115-1122, 2018.
Article in En | WPRIM | ID: wpr-718028
Responsible library: WPRO
ABSTRACT
PURPOSE: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. MATERIALS AND METHODS: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. RESULTS: This study included 217 eyes of 118 participants (20–81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20–44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased Corvis-IOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20–44 years, and over 44 years). CONCLUSION: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.
Subject(s)
Key words
Full text: 1 Database: WPRIM Main subject: Radius / Prospective Studies / Cornea / Observational Study / Intraocular Pressure / Methods Type of study: Observational_studies Limits: Humans Language: En Journal: Yonsei Medical Journal Year: 2018 Document type: Article
Full text: 1 Database: WPRIM Main subject: Radius / Prospective Studies / Cornea / Observational Study / Intraocular Pressure / Methods Type of study: Observational_studies Limits: Humans Language: En Journal: Yonsei Medical Journal Year: 2018 Document type: Article