Clinical characteristics and serious complications of esophageal button battery ingestion in the pediatric on 83 cases / 中华耳鼻咽喉头颈外科杂志
Chinese Journal of Otorhinolaryngology Head and Neck Surgery
; (12): 481-485, 2023.
Article
in Zh
| WPRIM
| ID: wpr-986916
Responsible library:
WPRO
ABSTRACT
Objective:
To analyze the clinical characteristics and complications of esophageal foreign bodies of button battery ingestion in children.Methods:
A retrospective descriptive study included 83 children who were hospitalized in our hospital on account of button battery ingestion from January 2011 to December 2021. There were 50 males (60.2%) and 33 females (39.8%). The age ranged from 7.6 months to one month off 10 years, with a median age of 18 months. The data of patient demographics and time from ingestion to admission, location, symptoms, management, complications, and follow-up outcome were recorded. SPSS17.0 software was used for statistical analysis.Results:
Seventy-two children (86.7%) were younger than 3 years old. The time from ingestion to admission ranged from 1 h to 2 months, with a median time of 8 h. Among the 63 children who were first diagnosed in our hospital, the most common clinical symptoms were nausea and vomiting (32 cases, 50.8%), dysphagia (31 cases, 49.2%), salivation (11 cases, 17.5%) and fever (10 cases, 15.9%). Seventy-three of 83 cases had complete preoperative diagnostic tests, and 55 cases (75.3%) were diagnosed by X-ray. In 56 cases (76.7%), the foreign badies were impacted in the upper third of esophagus. In 72 cases (86.7%), the foreign badies were removed by rigid esophagoscopy. 23 (27.7%) had serious complications, including tracheoesophageal fistula in 15 cases(TEF;65.2%), vocal cord paralysis (VCP;34.8%) in 8 cases, esophageal perforation in 3 cases (EP;13.0%), hemorrhage in 3 cases(13.0%), mediastinitis in 3 cases (13%), and periesophageal abscess in 1 case (4.3%). There were significant differences in the exposure time of foreign bodies and unwitnessed ingestion by guardians in the complications group (P<0.05). 2 cases died (2.4%)respectively due to arterial esophageal fistula bleeding and respiratory failure caused by stent displacement during the treatment of tracheoesophageal fistula.Conclusion:
Accidental button battery ingestion can be life-threatening. and it mostly happens in children under 3 years old. Serious complications may happen cause of non-specific clinical manifestations and unwitnessed ingestions. Anterior and lateral chest X-ray is the first examination choice. Tracheoesophageal fistula is the most common serious complication.
Full text:
1
Database:
WPRIM
Main subject:
Retrospective Studies
/
Tracheoesophageal Fistula
/
Eating
/
Foreign Bodies
Limits:
Child
/
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
Language:
Zh
Journal:
Chinese Journal of Otorhinolaryngology Head and Neck Surgery
Year:
2023
Document type:
Article