Your browser doesn't support javascript.
loading
Efeito de diferentes protocolos fotoativadores e espessura dos incrementos na dureza de resinas Bulk fill / Effect of lightcure protocols and increment thickness in the hardness of Bulk fill composites
Obeid, Alyssa Teixeira; Coneglian, Laís Campanholi; Albergaria, Laís Santos; Scotti, Cassiana Koch; Bombonatti, Juliana Fraga Soares.
Afiliación
  • Obeid, Alyssa Teixeira; s.af
  • Coneglian, Laís Campanholi; s.af
  • Albergaria, Laís Santos; s.af
  • Scotti, Cassiana Koch; s.af
  • Bombonatti, Juliana Fraga Soares; Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Dentística, Endodontia e Materiais Odontológicos. Bauru. BR
Rev. Odontol. Araçatuba (Impr.) ; 41(2): 34-39, maio-ago.2020. tab, graf
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1102682
Biblioteca responsable: BR186.1
Ubicación: BR186.1
RESUMO
As resinas Bulk fill surgiram com o intuito de facilitar a restauração de cavidades profundas. A fotoativação adequada é extremamente importante para que a resina bulk fill ofereça propriedades mecânicas satisfatórias e, longevidade na restauração. Este estudo avaliou a influência da espessura do incremento na microdureza Knoop (KHN) de três resinas bulk fill (n = 5). Cinquenta amostras foram divididas de acordo com o material (Filtek Z250, Filtek One Bulk Fill e Filtek Bulk Fill Flow), espessura (2mm e 4 mm) e tempo de fotoativação (20 e 40s) - Z2502mm20s, Z2502mm40s, One2mm20s, One2mm40s, One4mm20s, One4mm40s, Flow2mm20s, Flow2mm40s, Flow4mm20s e Flow4mm40s. As análises KHN foram realizadas no topo e na base de cada amostra. Os dados foram submetidos à ANOVA a 1 critério e ao Teste de Tukey (p< 0,05). A média e desvio padrão (+/-) dos seguintes grupos foram (Z2502mm20s) 0,85 (+/- 0,01); (Z2502mm40s) 0,92 (+/- 0,01); (One2mm20s) 1,05 (+/- 0,08); (One2mm40s) 0,95 (+/- 0,04); (One4mm20s) 0,93 (+/- 0,04); (One4mm40s) 0,97 (+/ - 0,04); (Flow2mm20s) 0,92 (+/- 0,05); (Flow2mm40s) 0,89 (+/- 0,04); (Flow4mm20s) 0,79 (+/- 0,04) e (Flow4mm40s) 0,90 (+/- 0,03). Os grupos da Filtek One Bulk apresentaram um valor significativamente maior, demonstrando uma polimerização suficiente mesmo na base de incrementos com 4 mm. Concluiu-se que o aumento na espessura do incremento de resinas bulk fill não afetou negativamente a fotoativação(AU)
ABSTRACT
Bulk fill composites emerged, allowing the restoration of deep cavities easily. Appropriate lightcuring is crucial to bulk fill composite presents satisfactory mechanical properties and restoration longevity. This study evaluated the influence of thickness increment on Knoop microhardness (KHN) of three dental bulk fill composites (n=5). Fifty samples were divided according to composite (Filtek Z250, Filtek One Bulk Fill and Filtek Bulk Fill Flow), thickness (2mm and 4 mm) and time lightcuring (20 and 40 s) - Z2502mm20s, Z2502mm40s, One2mm20s, One2mm40s, One4mm20s, One4mm40s, Flow2mm20s, Flow2mm40s, Flow4mm20s e Flow4mm40s. KHN analysis were performed on the top and the base of each specimen. Data were subjected to one-way ANOVA and Tukey test (p< 0,05). The mean and standard deviation (+/-) of following groups were (Z2502mm20s) 0,85(+/-0,01); (Z2502mm40s) 0,92(+/- 0,01); (One2mm20s) 1,05(+/-0,08); (One2mm40s) 0,95(+/-0,04); (One4mm20s) 0,93 (+/-0,04); (One4mm40s) 0,97(+/-0,04); (Flow2mm20s) 0,92(+/- 0,05); (Flow2mm40s) 0,89(+/-0,04); (Flow4mm20s) 0,79(+/-0,04) e (Flow4mm40s) 0,90(+/-0,03) Filtek One Bulk groups present significantly higher value, demonstrating sufficient polymerization even on the base of 4 mm increments. It was concluded that the increase in the thickness increment of Bulk fill composites did not negatively affect the lightcure(AU)
Asunto(s)

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: BBO - Odontología / LILACS Asunto principal: Resinas Compuestas / Pruebas de Dureza Idioma: Portugués Revista: Rev. Odontol. Araçatuba (Impr.) Asunto de la revista: Medicina Bucal / Odontologia / Odont¢logos / Sa£de Bucal Año: 2020 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR
Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: BBO - Odontología / LILACS Asunto principal: Resinas Compuestas / Pruebas de Dureza Idioma: Portugués Revista: Rev. Odontol. Araçatuba (Impr.) Asunto de la revista: Medicina Bucal / Odontologia / Odont¢logos / Sa£de Bucal Año: 2020 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade de São Paulo/BR
...