Your browser doesn't support javascript.
loading
Desarrollo y validación de un método de cromatografía gaseosa para la determinación de mentol, salicilato de metilo, timol y ácido benzoico en solución antiséptica / Development and validation of a gas chromatographic method for the determination of menthol, methyl salicylate, thymol, and benzoic acid in antiseptic solution
Fonseca Gola, Antonio; Cordoví Velázquez, Juan Manuel; Benítez Guerra, Niurka; Fernández Cervera, Mirna.
Afiliación
  • Fonseca Gola, Antonio; Laboratorio Farmacéutico Líquidos Orales de Bayamo. Bayamo. CU
  • Cordoví Velázquez, Juan Manuel; Joven Club de Computación. Bayamo. CU
  • Benítez Guerra, Niurka; Laboratorio Farmacéutico Líquidos Orales de Bayamo. Bayamo. CU
  • Fernández Cervera, Mirna; Universidad de La Habana. La Habana. CU
Rev. colomb. ciencias quim. farm ; 49(2): 306-328, May-Aug. 2020. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1144354
Biblioteca responsable: CO304.1
RESUMEN
RESUMEN Se desarrolló y validó un método por cromatografía gaseosa para la cuantificación simultánea de mentol (MT), salicilato de metilo (SM), timol (TM) y ácido benzoico (AB) en una solución antiséptica bucal. Se utilizó una columna DB-WAX y dietilenglicol como estándar interno. Se determinó la linealidad en un intervalo de concentraciones de 64,00 a 96,00 µg/mL (MT), 80,00 a 120,00 µg/mL (SM), 96,00 a 144,00 µg/mL (TM) y 48,00 a 72,00 µg/mL (AB), obteniendo coeficientes de correlación superiores a 0,999, y coeficientes de variación de los factores de respuestas de 1,18, 1,95, 3,52 y 1,48%, respectivamente. Se establecieron límites de detección de 0,51; 1,14; 3,34 y 1,402 ng/mL para el MT, SM, TM y AB, respectivamente, mientras los límites de cuantificación fueron de 1,45, 3, 43, 9, 73 y 4, 36 ng/mL en cada caso. Los porcentajes de recuperación fueron de 100,03, 99, 31, 99, 92 y 100,12; con coeficientes de variación de 0,42, 0,79, 0,66 y 0,76% para cada caso. El método fue lineal, exacto, preciso y selectivo para la determinación de los analitos en el control de calidad.
ABSTRACT
SUMMARY A method was developed and validated by gas chromatography for the simultaneous quantification of menthol (MT), methyl salicylate (SM), thymol (TM) and benzoic acid (AB) in an oral antiseptic solution. A DB-WAX column and diethylene glycol was used as internal standard. Linearity was determined in a concentration range of 64.00 to 96.00 µg/mL (MT), 80.00 to 120.00 µg/mL (SM), 96.00 to 144.00 µg/mL (TM) and 48.00 to 72.00 µg/mL (AB) achieving correlation coefficients greater than 0.999, and coefficients of variation of the response factors of 1.18, 1.95, 3.52 and 1.48%, respectively. Detection limits were established 0.51, 1.14, 3.34 and 1.402 ng/mL for MT, SM, TM, and AB, respectively, while the quantification limits were 1.45, 3.43, 9.73 and 4.36 ng/mL in each case. Recovery percentages were 100.03, 99.31, 99.92 and 100.12; with coefficients of variation of 0.42, 0.79, 0.66 and 0.76% for each case. The method was linear, accurate, precise, and selective for the determination of analytes in quality control.


Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Idioma: Español Revista: Rev. colomb. ciencias quim. farm Asunto de la revista: Farmacia / Química Año: 2020 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Joven Club de Computación/CU / Laboratorio Farmacéutico Líquidos Orales de Bayamo/CU / Universidad de La Habana/CU

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Idioma: Español Revista: Rev. colomb. ciencias quim. farm Asunto de la revista: Farmacia / Química Año: 2020 Tipo del documento: Artículo País de afiliación: Cuba Institución/País de afiliación: Joven Club de Computación/CU / Laboratorio Farmacéutico Líquidos Orales de Bayamo/CU / Universidad de La Habana/CU
...