Your browser doesn't support javascript.
loading
Mid- to long-term clinical and echocardiographic outcomes after transcatheter aortic valve replacement with a newgeneration, self-expandable system / Desfechos clínicos e ecocardiográficos de médio a longo prazo após a substituição da válvula aórtica transcateter com uma nova geração, sistema auto-expansível
Siqueira, Dimytri A; Simonato, Matheus; Ramos, Auristela A; Bignoto, Tiago; Le Bihan, David; Barreto, Rodrigo B M; Senra, Tiago; Pinto, Ibraim M; Kambara, Antonio M; Santos, Magaly A; Viana, Renata; Sousa, Amanda G M R; Abizaid, Alexandre A C.
Afiliación
  • Siqueira, Dimytri A; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Simonato, Matheus; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Ramos, Auristela A; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Bignoto, Tiago; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Le Bihan, David; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Barreto, Rodrigo B M; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Senra, Tiago; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Pinto, Ibraim M; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Kambara, Antonio M; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Santos, Magaly A; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Viana, Renata; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Sousa, Amanda G M R; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Abizaid, Alexandre A C; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
Catheter. cardiovasc. interv ; 97(1): 167-174, May. 2020. graf, ilus, tab
Article en En | CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1145584
Biblioteca responsable: BR79.1
Ubicación: BR79.1
ABSTRACT
Abstract

Objectives:

The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with A curate neo™ (Boston Scientific, Boston, MA).

Background:

TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves.

Methods:

All consecutive patients (n = 104) who underwent A curate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions.

Results:

Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5­4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months.

Conclusions:

A curate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.
Asunto(s)

Texto completo: 1 Colección: 06-national / BR Base de datos: CONASS / SES-SP / SESSP-IDPCPROD Asunto principal: Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Idioma: En Revista: Catheter. cardiovasc. interv Año: 2020 Tipo del documento: Article

Texto completo: 1 Colección: 06-national / BR Base de datos: CONASS / SES-SP / SESSP-IDPCPROD Asunto principal: Estenosis de la Válvula Aórtica / Reemplazo de la Válvula Aórtica Transcatéter Idioma: En Revista: Catheter. cardiovasc. interv Año: 2020 Tipo del documento: Article
...