Confiabilidade da baropodometria na avaliação do equilíbrio de indivíduos com deficiência visual / Reliability of baropodometry in assessing the balance of individuals with visual impairment
Acta fisiátrica
; 28(2): 78-85, jun. 2021.
Article
en Pt
|
LILACS-Express
| LILACS
| ID: biblio-1348726
Biblioteca responsable:
BR1531.9
RESUMO
Indivíduos com deficiência visual podem apresentar déficits de equilíbrio e existem diversos métodos capazes de avalia-lo, sendo a baropodometria um método em expansão, porém com escassez de estudos que abordem suas medidas psicométricas e avaliações padronizados. Objetivo:
Avaliar a confiabilidade relativa e absoluta da baropodometria em um protocolo de avaliação de equilíbrio para pessoas com deficiência visual.Método:
Estudo observacional, de corte transversal, com 38 indivíduos, de ambos os sexos, com e sem diagnóstico de deficiência visual, sendo alocados grupo controle (GCO) (n= 13) composto por indivíduos sem deficiência visual, grupo baixa visão (GBV) (n= 15), grupo cegueira (GCE) (n= 10) e posteriormente realizada a junção do GBV e GCE, compondo o grupo deficiência visual (GDV) (n= 25). Para avaliar a confiabilidade da baropodometria, utilizou-se o método teste e reteste, com um intervalo de sete dias. Os indivíduos foram avaliados em três condições, apoio bipodal, apoio unipodal direito e apoio unipodal esquerdo considerando as variáveis área, amplitude e velocidade média anteroposterior e laterolateral. Para confiabilidade relativa foi utilizado o Coeficiente de Correlação Intraclasse (CCI) e para a confiabilidade absoluta o erro padrão da medida (EPM).Resultados:
Em relação a confiabilidade relativa, os CCIs das variáveis da baropodometria variaram de baixo a muito alto em todos os grupos, com melhor confiabilidade nas condições de apoios unipodais e maior índice no GCE. Na confiabilidade absoluta, 14 variáveis apresentaram boa confiabilidade.Conclusão:
A baropodometria apresenta-se como um método confiável, porém deve-se ter cautela na escolha do posicionamento e da variável a ser analisada.ABSTRACT
Individuals with visual impairment may have balance deficits and there are several methods capable of evaluating it, and baropodometry is an expanding method, but with a lack of studies that address its psychometric measures and standardized assessments. Objective:
To assess the relative and absolute reliability of baropodometry in a balance assessment protocol for visually impaired people.Methods:
Observational, cross-sectional study, with 38, of both sexes, with and without a diagnosis of visual impairment, were included in three groups control group (CG) (n= 13) composed of individuals without visual impairment, low vision group (LVG) (n= 15), blindness group (BG) (n= 10) and subsequently the LVG and BG were joined, making up the group visual impairment (VIG) (n= 25). To evaluate the reliability of baropodometry, the test and retest method was used, with an interval of seven days. The individuals were evaluated in three conditions, support bipedal, right unipodal support and left unipodal support considering the variables area, amplitude and mean anteroposterior and laterolateral speed. For relative reliability, the Intraclass Correlation Coefficient (ICC) was used and for absolute reliability the standard error of measurement (SEM).Results:
Regarding the relative reliability, the ICCs of the baropodometry variables varied from low to very high in all groups, with better reliability in the conditions of unipodal supports and a higher index in the BG. In absolute reliability, 14 variables showed good reliability.Conclusion:
Baropodometry is a reliable method, however, care must be taken when choosing the position and the variable to be analyzed.
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
Tipo de estudio:
Guideline
/
Observational_studies
/
Prevalence_studies
Idioma:
Pt
Revista:
Acta fisiátrica
Asunto de la revista:
MEDICINA FISICA E REABILITACAO
Año:
2021
Tipo del documento:
Article
País de afiliación:
Brasil
Pais de publicación:
Brasil