Tolerancia a la prueba ergométrica graduada al utilizar barbijo o tapaboca / Exercise Testing Tolerance when Using Face Mask
Rev. argent. cardiol
; 89(5): 466-469, oct. 2021. tab
Artículo
en Español
|
LILACS-Express
| LILACS
| ID: biblio-1356925
Biblioteca responsable:
AR1.1
RESUMEN
RESUMEN Introducción:
es poco conocida la tolerancia al ejercicio con el uso de barbijo.Objetivo:
investigar tolerancia al barbijo en ergometrías (PEG). Material ymétodos:
estudio multicéntrico con PEG con barbijo.Resultados:
118 PEG (62 cinta, 56 cicloergómetro), 68 hombres, edad 46,74 ± 16,7 años. Setenta (59,3%) completaron PEG con barbijo, 48 (40,7%) debieron retirarlo 17 en cinta (27,4%), 31 (55,4%) en bicicleta (p = 0,002). Porcentaje de frecuencia cardíaca al retirar barbijo con respecto a máxima alcanzada 94,5±5,35%. Edad de quienes retiraron barbijo 42,69±17,35 años y de quienes toleraron 49,51 ± 15,88 (p = 0,003). Saturación basal 97,46 ± 1,01%; en esfuerzo máximo con barbijo 96,58 ± 1,37% (p <0,0001). Al retirar barbijo, saturación de 97,06 ± 1,35% (p < 0.0001). Edad menor y uso de cicloergómetro fueron predictores de no tolerar el barbijo.Conclusiones:
la mayoría completó el ejercicio máximo con barbijo. La intensidad de ejercicio al retirar el barbijo fue alta. La saturación cayó en ejercicio con barbijo, aunque sin repercusión clínica.ABSTRACT
ABSTRACT Background:
Tolerance to exercise with the use of face mask is not well known.Objective:
The aim of this study was to investigate the tolerance of exercise parameters during exercise stress testing (EST) while wearing a face mask.Methods:
Multicenter study of EST while wearing face mask.Results:
118 ESTs (62 on treadmill, 56 on cycle ergometer), 68 men, age 46.74 ± 16.7 years. Seventy patients (59.3%) completed the EST wearing a face mask, and 48 (40.7%) removed it; 17 patients (27.4%) were on treadmill and 31 (55.4%) on cycle ergometer (p = 0.002). Percentage of maximum predicted heart rate attained when the patients removed their face mask 94.5 ± 5.35%. Age of those who removed the face mask 42.69 ± 17.35 years and of those who tolerated the face mask 49.51 ± 15.88 years (p = 0.003). Baseline SpO2 was 97.46 ± 1.01% and 96.58 ± 1.37% on peak exercise wearing face mask (p < 0.0001). SpO2 when the face mask was removed 97.06 ± 1.35% (p <0.0001). Younger age and use of cycle ergometer were predictors of intolerance to face mask.Conclusion:
Most patients completed peak exercise with face mask. Exercise intensity was high when the face mask was removed. Oxygen saturation dropped during exercise with face mask without clinical impact.
Texto completo:
Disponible
Colección:
Bases de datos internacionales
Base de datos:
LILACS
Tipo de estudio:
Ensayo clínico controlado
Idioma:
Español
Revista:
Rev. argent. cardiol
Asunto de la revista:
Cardiología
/
Doenas Cardiovasculares
Año:
2021
Tipo del documento:
Artículo
País de afiliación:
Argentina
Institución/País de afiliación:
Universidad Nacional de Rosario/AR