Your browser doesn't support javascript.
loading
Tempo de confecção clínica e laboratorial de placas oclusais convencionais x fresadas em pacientes com bruxismo do sono: ensaio clínico / Clinical and laboratory production time of conventional x milled occlusal splints in patients with sleep bruxism: clinical trial
Natal; s.n; 26 jul. 2022. 63 p. ilus, tab.
Tesis en Portugués | BBO - Odontología | ID: biblio-1513014
Biblioteca responsable: BR1264.1
RESUMO
O objetivo desse estudo foi comparar o tempo de confecção clínica, laboratorial e ajustes clínicos para a instalação de placas oclusais termopolimerizáveis convencionais (PC) e confeccionadas por CAD/CAM fresadas (PF) em pacientes com bruxismo do sono. Para tanto, foi realizado um ensaio clínico controlado e não randomizado onde foram incluídos pacientes com diagnóstico de provável bruxismo do sono. Foram confeccionadas PC (n = 24) e PF (n = 24) sendo mensurados o tempo de confecção clínica (TCC), tempo de confecção laboratorial (TCL) e tempo de instalação (TI) para cada uma das placas. Foi utilizado o teste Mann-whitney com nível de confiança de 95% no programa SPSS IBM Statistics para analisar se existe diferença entre os tempos analisados e o tipo de placa confeccionada. Como resultado, verificou-se que a PC possuiu maior TCC total (média de 94,39 min) em relação à PF (17,85 min) (p<0,001). Entretanto, o TCL total da PC foi menor (164,80 min), que a PF (182,64min) (p=0,015). Para o TI, foi encontrado que PF obteve uma média 21, 26 min, enquanto PC obteve 37,19 min (p<0,001). Como conclusão, dentro as limitações do estudo, observou-se que as placas fresadas apresentaram menor tempo clínico tanto na etapa de confecção quanto de instalação. Entretanto, o tempo de confecção laboratorial das placas convencionais foi inferior (AU).
ABSTRACT
The aim of the study was to compare the clinical and laboratory preparation time and clinical adjustments for the installation of conventional thermopolymerizable resin splint (CS) and milled CAD/CAM (MS) occlusal splints in patients with sleep bruxism. For this purpose, a controlled and non-randomized clinical trial was carried out in which patients diagnosed with probable sleep bruxism were included. CS (n = 24) and MS (n = 24) were prepared and the clinical preparation time (CPT), laboratory preparation time (LPT) and installation time (IT) were measured for each of the splints. The Mannwhitney test with a confidence level of 95% was used in the SPSS IBM Statistics program to analyze whether there is a difference between the analyzed times and the type splint performed. As a result, it was found that CS had higher total CPT (mean of 94,39 min) in relation to MS (17,85 min) (p0<001). However, the total LPT of the CS was lower (164,80 min) than the MS (182,64min) (p=0.015). For the IT, it was found that the MS had an average of 21,26 min, while the CS had 37,19min (p0<001). In conclusion, within the limitations of the study, it was observed that the milled splint had a shorter clinical time both in the manufacturing and installation stages. However, the laboratory preparation time of the conventional splint was shorter (AU).
Asunto(s)

Texto completo: Disponible Colección: Bases de datos nacionales Base de datos: BBO - Odontología Asunto principal: Ferulas Oclusales / Bruxismo del Sueño / Oclusión Dental / Desgaste de los Dientes Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Año: 2022 Tipo del documento: Tesis
Texto completo: Disponible Colección: Bases de datos nacionales Base de datos: BBO - Odontología Asunto principal: Ferulas Oclusales / Bruxismo del Sueño / Oclusión Dental / Desgaste de los Dientes Límite: Adulto / Femenino / Humanos / Masculino Idioma: Portugués Año: 2022 Tipo del documento: Tesis
...