Your browser doesn't support javascript.
loading
Evolución de las cajas de polyetheretherketone (PEEK). Estudio clínico y radiológico / Évolution des cages en polyétheréthercétone (PEEK). Étude clinique et radiologique / Evolution of polyetheretherketone (PEEK) boxes. Clinical and radiological study
Sánchez Hidalgo, Ricardo; Asenjo Siguero, Juan José; Rodríguez-Macías, María Jesús; García Delgado, Ignacio; Varillas Delgado, David; Javier Martínez, Elías Emmanuel; García de Lucas, Fernando.
Afiliación
  • Sánchez Hidalgo, Ricardo; Hospital FREMAP. Madrid. ES
  • Asenjo Siguero, Juan José; Hospital FREMAP. Madrid. ES
  • Rodríguez-Macías, María Jesús; Hospital FREMAP. Madrid. ES
  • García Delgado, Ignacio; Hospital FREMAP. Madrid. ES
  • Varillas Delgado, David; Hospital FREMAP. Madrid. ES
  • Javier Martínez, Elías Emmanuel; Hospital FREMAP. Madrid. ES
  • García de Lucas, Fernando; Hospital FREMAP. Madrid. ES
Rev. cuba. ortop. traumatol ; 31(1): 50-60, ene.-jun. 2017. ilus, tab
Artículo en Español | LILACS, CUMED | ID: biblio-901402
Biblioteca responsable: CU1.1
RESUMEN

Introducción:

las cajas cervicales son implantes desarrollados como una alternativa a la utilización del injerto óseo estructural para la fusión cervical anterior. El objetivo de este estudio fue analizar la clínica y los resultados radiológicos en una serie de pacientes sometidos a disectomía y descompresión cervical anterior, a los que se les implantó una caja PEEK.

Método:

estudio retrospectivo, descriptivo, longitudinal de una serie de 78 pacientes incluidos en el estudio desde el año 2007 al 2013. El control radiológico incluyó radiografía anteroposterior y lateral. El seguimiento clínico y radiológico de los pacientes se llevó a cabo desde los 3 meses hasta los 12 meses.

Resultados:

65 pacientes tuvieron una evolución clínica favorable (83,3 por ciento) y la evolución radiológica confirmó que 66 pacientes (84,6 por ciento) tenían una buena colocación del injerto, sin lesiones en espacios adyacentes con una fusión correcta.

Conclusiones:

hasta la fecha hay pocos estudios descriptivos sobre el implante de las cajas PEEK, los resultados mostrados en este trabajo están acordes a los publicados con anterioridad en este mismo campo, lo que da validez al trabajo presentado. Este estudio confirma los buenos resultados clínicos y radiológicos de pacientes a los que se les implantó una caja PEEK; se muestra su eficacia en la discectomía cervical anterior y artrodesis(AU)
ABSTRACT

Introduction:

Cervical cases are implants developed as an alternative to the use of structural bone graft for anterior cervical fusion. The objective of this study was to analyze the clinical and radiological results in a series of patients submitted to anterior cervical dissectomy and decompression, to whom a PEEK box was implanted.

Method:

A retrospective, descriptive, longitudinal study was conducted in a series of 78 patients included in the study from 2007 to 2013. Radiological control included anteroposterior and lateral radiographies. Clinical and radiological follow-up of these patients was carried out from 3 months to 12 months.

Results:

65 patients had a favorable clinical course (83.3 percent) and the radiological evolution confirmed that 66 patients (84.6 percent) had a good placement of the graft without lesions in adjacent spaces with a correct fusion.

Conclusions:

To date there are few descriptive studies on the implantation of PEEK boxes. This paper results are in line with those published previously in this same field, which legitimate the presented work. This study confirms the good clinical and radiological results in patients who were implanted with a PEEK box; its effectiveness in anterior cervical discectomy and arthrodesis is shown(AU)

Introduction:

Les cages cervicales sont des implants développés comme alternative de la greffe osseuse structurelle pour la fusion cervicale antérieure. Le but de cette étude est d'analyser la technique et les résultats radiologiques dans une série de patients traités par discectomie et décompression cervicale antérieure, et implantation d'une cage PEEK. Méthodes Étude rétrospective, descriptive et longitudinale d'une série de 78 patients inclus dans une étude depuis l'année 2007 jusqu'à l'année 2013. L'étude radiologique a compris des clichés en position antéro-postérieure et latérale. Le suivi clinique et radiologique des patients a pris de 3 à 12 mois. Résultats L'évolution clinique a été satisfaisante chez 65 patients (83,3 pourcent), tandis que l'étude radiologique a confirmé que le greffon était bien placé, il n'y avait pas de lésions dans les espaces adjacentes, et la fusion était correcte chez 66 patients (84,6 pourcent).

Conclusions:

Jusqu'à maintenant, il y a peu d'études descriptives abordant l'implantation des cages PEEK. Le présent travail est validé, car ses résultats sont en concordance avec les travaux publiés auparavant dans ce domaine. Cette étude confirme les bons résultats obtenus chez les patients ayant subi l'implantation d'une cage PEEK ; son efficacité est démontrée dans la discectomie cervicale antérieure et l'arthrodèse(AU)
Asunto(s)

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: CUMED / LILACS Asunto principal: Artrodesis / Discectomía / Autoevaluación Diagnóstica Tipo de estudio: Estudio diagnóstico / Estudio observacional Límite: Adulto / Anciano / Humanos Idioma: Español Revista: Rev. cuba. ortop. traumatol Asunto de la revista: Ortopedia / Traumatología Año: 2017 Tipo del documento: Artículo País de afiliación: España Institución/País de afiliación: Hospital FREMAP/ES
Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: CUMED / LILACS Asunto principal: Artrodesis / Discectomía / Autoevaluación Diagnóstica Tipo de estudio: Estudio diagnóstico / Estudio observacional Límite: Adulto / Anciano / Humanos Idioma: Español Revista: Rev. cuba. ortop. traumatol Asunto de la revista: Ortopedia / Traumatología Año: 2017 Tipo del documento: Artículo País de afiliación: España Institución/País de afiliación: Hospital FREMAP/ES
...