Your browser doesn't support javascript.
loading
Escala de Epwoth y cuestionario de Stop Bang como predictores del síndrome de apneas hipopneas obstructivas del sueño / Epworth Sleepiness Scale and Stop Bang questionnaire as predictors for the obstructive sleep apnea syndrome / Escala de Epworth e questionário PARAR BANG como preditores de hipopnéias apneia obstrutiva do sono. Síndrome do sono
Aramendi, Mariana; Patrucco, Marta; Novello, Liliana.
Afiliación
  • Aramendi, Mariana; Complejo Médico Policial Churruca Visca. Servicio de Otorrinolaringología. CABA. AR
  • Patrucco, Marta; Complejo Médico Policial Churruca Visca. Sección Laringología, Voz, Deglución y Cirugía de Cabeza y Cuello. CABA. AR
  • Novello, Liliana; Complejo Médico Policial Churruca Visca. Servicio de Otorrinolaringología. CABA. AR
Rev. Fed. Argent. Soc. Otorrinolaringol ; 24(1): 62-68, 2017. ilus, tab
Artículo en Español | LILACS | ID: biblio-908126
Biblioteca responsable: AR635.1
RESUMEN
Introducción: El SAHOS (Síndrome de Apneas e Hipopneas Obstructivas del Sueño) surge de apneas e hipopneas que generan una hipoxia intermitente. La polisomnografía es el gold standard para su diagnóstico. La Escala de Somnolencia de Epworth (ESS) identifica pacientes con somnolencia diurna. El cuestionario Stop Bang reconoce pacientes con riesgo de SAHOS. El objetivo es describir la sensibilidad y especificidad de la ESS y Stop Bang para el diagnóstico de SAHOS realizado con polisomnografía. Métodos: 125 pacientes completaron la ESS, Stop Bang y realizaron una polisomnografía de noche completa. Se confeccionaron dos grupos: pacientes con IAH < 15, y pacientes con IAH ≥ 15. Se calcularon sensibilidad, especificidad, razón de probabilidades (OR) y curvas ROC para el diagnóstico de SAHOS de la ESS y el Stop Bang. Resultados: La prevalencia del grupo IAH ‹ 15 fue de 36%, y del grupo IAH ≥ 15 fue de 64%. Para la ESS, 71 pacientes presentaron somnolencia diurna, 49,3% con un IAH < 15 y 50,7% con un IAH ≥ 15. Especificidad 77,78%, sensibilidad 55%, área bajo la curva ROC 0,6553. Para el cuestionario Stop Bang, 110 pacientes presentaron alto riesgo para SAHOS, 30% con un IAH < 15 y 70% con IAH ≥ 15. Especificidad 26,67%, sensibilidad 96,25%, área bajo la curva ROC 0,7671. Se enfrentaron ambos cuestionarios y calcularon sus OR: ESS, OR=1,1014 (p=0,038); Stop Bang, OR=8,099 (p=0,002). Conclusiones: La sensibilidad de ESS es baja y su área bajo la curva ROC poco significativa. La gran sensibilidad del cuestionario Stop Bang junto con su área bajo la curva ROC, lo convierten en una herramienta de importancia para realizar screening de SAHOS.
ABSTRACT
Introduction: osa (obstructive sleep apnea) arises from apneas and hypopneas that cause intermittent hypoxia. Polysomnography is the gold standard for its diagnosis. The Epworth Sleepiness Scale (ESS) measures daytime sleepiness. The Stop Bang Questionnaire (SBQ) recognizes patients at risk of OSA. Objectives: describe the sensitivity and specificity of the ESS and SBQ for the diagnosis of OSA accomplished by polysomnography. Methods: 125 adult patients completed the ESS, SBQ and a full night polysomnography. Patients were grouped into two: those with AHI < 15 and those with AHI ≥ 15. Sensibility, specificity, odds ratio (OR) and ROC curves were determined for the ESS and SBQ. Results: The group with AHI ≥ 15 prevailed (64%). 71 patients (56.8%) showed an abnormal ESS´s score; 49.3% showed an AHI < 15 and 50.7% AHI ≥ 15. The specificity was 77.78% and sensitivity 55%. The area under the ROC curve was 0.6553. Regarding the SBQ, 110 patients were within the high risk group; 30% corresponded to an AHI < 15 and 70% AHI ≥ 15. The specificity was 26.67% and sensitivity 96.25%. The area under the ROC curve was 0.7671. The OR for the ESS was 1.1014 (p=0.038) and SBQ, OR = 8.099 (p=0.002). Conclusion: The sensitivity of the ESS is low and the area under the ROC curve insubstantial. The SBQ shows high sensitivity and a remarkable area under the ROC curve, which turn it into an important tool for screening OSA.
RESUMO
Introdução: sahos (síndrome da apneia e hipopneia obstrutiva do sono) surge de apnéias e hipopnéias que geram hipóxia intermitente. A polissonografia (PSG) é o gold standard para o diagnóstico. A Escala de Sonolência de Epworth (ESS) identifica pacientes com sonolência diurna. O questionário Stop bang reconhece pacientes em risco de doenca de SAHOS. O objetivo de este trabalho é descrever a sensibilidade e especificidade da ESS e do questionario Stop Bang para diagnóstico de SAHOS feito coma PSG. Métodos: 125 pacientes completaram a ess, o stop bang efisseram uma psg con oximetria de noite completa. Dividiram-se os pacientes em dois grupos: com IAH < 15 e 50,7% com um IAH ≥ 15. A especificidade foi de 77,78%, a sensibilidade de 55%, e a área abaixo da curva ROC 0,6553. Enquanto ao questionário stop bang, 110 pacientes apresentaram alto risco de SAHOS, 30% com um IAH < 15 e 70% com IAH ≥ 15. Especificidade de 26,67%, 96,25% de sensibilidade, e 0,7671 da área abaixo da curva. Se comparam ambos questionários e foi calculada sua OR: ESS, OR = 1,1014 (p = 0,038); Stop Bang, OR = 8,099 (p = 0,002). Conclusões: a sensibilidade ess é baixa e a área baixo da curva roc insignificante. A alta sensibilidade do questionário Stop Bang junto com a área baixo da curva ROC o tornam uma ferramenta muito importante para o sreening de esta doença.
Asunto(s)

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Asunto principal: Técnicas y Procedimientos Diagnósticos / Apnea Obstructiva del Sueño Tipo de estudio: Estudio diagnóstico / Estudio de evaluación / Estudio pronóstico / Factores de riesgo Límite: Humanos Idioma: Español Revista: Rev. Fed. Argent. Soc. Otorrinolaringol Asunto de la revista: Otolaringologia Año: 2017 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Complejo Médico Policial Churruca Visca/AR
Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Asunto principal: Técnicas y Procedimientos Diagnósticos / Apnea Obstructiva del Sueño Tipo de estudio: Estudio diagnóstico / Estudio de evaluación / Estudio pronóstico / Factores de riesgo Límite: Humanos Idioma: Español Revista: Rev. Fed. Argent. Soc. Otorrinolaringol Asunto de la revista: Otolaringologia Año: 2017 Tipo del documento: Artículo País de afiliación: Argentina Institución/País de afiliación: Complejo Médico Policial Churruca Visca/AR
...