Prevención de extubación no programada en pacientes con ventilación mecánica invasiva / Prevention of non-programed tube-extractions among patients with invasive mechanical ventilation / Prevenção de extubação não programada em pacientes com ventilação mecânica invasiva
Enferm. univ
; 15(3): 255-264, jul.-sep. 2018. tab, graf
Article
en Es
|
LILACS-Express
| LILACS, BDENF
| ID: biblio-975118
Biblioteca responsable:
MX17.1
Ubicación: MX17.1; 15
RESUMEN
Introducción Las extubaciones no programadas constituyen un evento adverso frecuente y de alto impacto, en la mayoría de los casos la presencia de este evento se relaciona con factores como la vía aérea, ventilación mecánica, nivel de sedación, estado y actividad mental del paciente, entre otros también prevenibles. Por ello, se establece un indicador de calidad para prevenir extubaciones no programadas en pacientes con ventilación mecánica invasiva y tubo endotraqueal. Objetivo Realizar la validación de contenido del indicador y describir el nivel de cumplimiento para la prevención de extubaciones no programadas en pacientes con ventilación mecánica invasiva en un hospital de tercer nivel de la Ciudad de México, con el propósito de dar a conocer nuevos aportes en materia de prevención. Metodología Estudio cuantitativo y descriptivo, con una muestra no probabilística a conveniencia conformada por 46 procesos observados durante el turno matutino en tres servicios de hospitalización. Resultados Se encontró que el 96% de los procesos observados arrojaron un nivel de prevención medio para las extubaciones no programadas. Al evaluar el índice de eficiencia global del indicador, se obtuvo un resultado del 59.8%, lo cual muestra que las acciones para prevenir una extubación no programada se cumplen en un porcentaje muy bajo. Conclusiones Se detectó una omisión de funciones por los profesionales de la salud en la prevención de este evento, por lo que se propuso un plan de mejora para la institución con el propósito de disminuir los eventos relacionados a las extubaciones.
ABSTRACT
Introduction Non-programed extubation, constitute a frequent high impact adverse event involving issues on the airway, mechanical ventilation, sedation level, patient´s mental activity, among others. Because of this, a quality indicator is established in order to help prevent non-programed extubation among patients with invasive mechanical ventilation and endotracheal tube. Objective To perform a validation of content on this indicator in a third level hospital of the City of Mexico, and describe the level of adherence to its components in order to prevent non-programed extubation among patients with invasive mechanical ventilation and endotracheal tube, and share the resulting contributions in the area of prevention. Methodology This is a quantitative and descriptive study with a non-probabilistic sample by convenience of 46 processes which were observed during the morning shifts in three hospitalization services. Results It was found that 96% of the processes observed showed an insufficient level of prevention of non-programed extubation. The assessment of the efficiency related to indicator´s components showed a 59.8% compliance, suggesting that the actions to prevent non-programed extubation are not sufficiently taken. Conclusions An important related omission by health professionals regarding the prevention of this kind of adverse events was detected, and thus, a corresponding improvement plan for the institution was proposed.
RESUMO
Introdução As extubaçãos não programadas constituem um evento adverso frequente e de alto impacto, na maioria dos casos, a presença deste evento relaciona-se com fatores como a via aérea, ventilação mecânica, nível de sedação, estado e atividade mental do paciente, entre outros, também preveníeis. Por isso, estabelece-se um indicador de qualidade para prevenir extubaçãos não programadas em pacientes com ventilação mecânica invasiva e tubo endotraqueal. Objetivo Realizar a validação de conteúdo do indicador e descrever o nível de cumprimento para a prevenção de extubaçãos não programadas em pacientes com ventilação mecânica invasiva em um hospital de terceiro nível da Cidade do México, com o propósito de dar a conhecer novas contribuições em matéria de prevenção. Metodologia Estudo quantitativo e descritivo, com uma amostra não probabilística a conveniência, conformada por 46 processos observados durante o turno matutino em três serviços de hospitalização. Resultados Encontrou-se que o 96% dos processos observados revelaram um nível de prevenção médio para as extubaçãos não programadas. Avaliando o índice de eficiência global do indicador, obteve-se um resultado do 59.8%, o qual mostra que as ações para prevenir uma extubação não programada cumprem-se em uma porcentagem muito baixa. Conclusões Identificou-se uma omissão de funções pelos profissionais da saúde na prevenção deste evento, pelo que se propus um plano de melhora para a instituição com o propósito de diminuir os eventos relacionados às extubaçãos.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
BDENF
/
LILACS
Tipo de estudio:
Prognostic_studies
Límite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Newborn
Idioma:
Es
Revista:
Enferm. univ
Asunto de la revista:
ENFERMAGEM
Año:
2018
Tipo del documento:
Article
País de afiliación:
México
Pais de publicación:
México