Comparación de la solubilidad de tres resinas acrílicas de autocurado utilizadas para la confección de coronas provisionales inmersas en diferentes soluciones y en distintos tiempos de exposición / Comparison of the solubility of three autocured acrylic resins used for the manufacture of immersive provisional crowns in different solutions and in different times of exposure
Rev. cient. odontol
; 5(1): 603-612, ene.-jun. 2017. ilus, tab
Artículo
en Español
| LILACS
| ID: biblio-999304
Biblioteca responsable:
PE391.9
RESUMEN
Objetivo:
Comparar la solubilidad de tres resinas acrílicas de autocurado inmersas en diferentes soluciones y en distintos tiempos de exposición. Materiales yMétodo:
Se confeccionaron 12 grupos de 3 discos cada uno, cada grupo fue integrado por una resina acrílica y un solvente, las cuales fueron evaluados a las 24 hrs, los mismos discos a las 48 hrs, a la semana y al mes.Resultados:
El valor de máxima solubilidad en la resina acrílica Duralay fue de 0.093 en el disolvente etanol, mientras que el valor mínimo de solubilidad fue la que evidenció la resina acrílica Alike con 0.005 en el disolvente agua. Además se demostró que la gaseosa fue el solvente que ocasionó mayor captación de agua y pigmentos en las muestras de prueba, considerándolo ineficiente para la durabilidad de las coronas de autocurado.Conclusiones:
Las resinas acrílicas presentaron cambios volumétricos significativos, principalmente la gaseosa fue la que mas dilatación causó y el que mostró menor grado de solubilidad fue la resina Alike en comparación con las otras resinas acrílicas. (AU)ABSTRACT
Objective:
To compare the solubility of three curing acrylic resins immersed in different solutions at different exposure times.Material andMethods:
Twelve groups of 3 discs each one were made, each group consisting of an acrylic resin and a solvent, which were evaluated at 24hrs, the same discs at 48hrs, a week and a month.Results:
The value of maximun solubility in the Duralay acrylic resin was 0.093 in the ethanol solvent, while the minimum value of solubility was that evidenced by Alike acrylic resin with 0.005 in the water solvent. In addition, it was demonstrated that the soda was the solvent that caused greater uptake of water and pigments in the test samples, considering it inefficient for the durability of the self-healing crowns.Conclusions:
The acrylic resins showed significant volumetric changes, mainly the gaseous was the one that caused more dilation and the one that showed Lesser solubility was the Alike resin compared to the other acrylic resins. (AU)
Texto completo:
Disponible
Colección:
Bases de datos internacionales
Contexto en salud:
ODS3 - Meta 3.9 Reducir las muertes producidas por productos químicos peligrosos y la contaminación del aire, el agua y el suelo
Problema de salud:
Exposiciones Ocupacionales
Base de datos:
LILACS
Asunto principal:
Polímeros
/
Solubilidad
/
Resinas Acrílicas
/
Coronas
Límite:
Humanos
Idioma:
Español
Revista:
Rev. cient. odontol
Asunto de la revista:
Odontologia
Año:
2017
Tipo del documento:
Artículo
País de afiliación:
Perú
Institución/País de afiliación:
Universidad Científica del Sur/PE