Evaluación de la glucemia a través de dos métodos analíticos en la atención de urgencia / Assessment of Blood Glucose Levels by Two Analytic Methods in the Emergency Room
Pérez Berlanga, Ana María; Rodríguez Diéguez, Margarita; Hernández Piferrer, Gretel; Tribín Rivero, Kenia; Pérez Pupo, Annarelis.
Afiliación
  • Pérez Berlanga, Ana María; Hospital General Universitario Vladimir Ilich Lenin. Holguín. Cuba
  • Rodríguez Diéguez, Margarita; Hospital General Universitario Vladimir Ilich Lenin. Holguín. Cuba
  • Hernández Piferrer, Gretel; Hospital Clínico-Quirúrgico Docente Lucía Íñiguez. Holguín. Cuba
  • Tribín Rivero, Kenia; Hospital Clínico-Quirúrgico Docente Lucía Íñiguez. Holguín. Cuba
  • Pérez Pupo, Annarelis; Hospital General Universitario Vladimir Ilich Lenin. Holguín. Cuba
CCM ; 18(4): 664-675, oct 2014. graf, tab
Article en Es | CUMED | ID: cum-65471
Biblioteca responsable: CU422.1
Ubicación: CU422.1
RESUMEN
Introducción: la medición de un mismo parámetro en Medicina por diferentes métodos exige comprobaciones de concordancia entre estos.Objetivo: determinar el desacuerdo, entre la glucemia obtenida mediante un glucómetro y el método habitual de laboratorio en pacientes atendidos en Cuerpo de Guardia.Métodos: estudio observacional descriptivo de serie de casos en pacientes que acudieron a Cuerpo de Guardia del Hospital Vladimir Ilich Lenin de Holguín, Cuba, durante marzo de 2013, que requirieron determinación de glucemia. El tamaño muestral se calculó sobre la base del 5 por ciento de desacuerdo esperado por las normas de la International Organization for Standardization (ISO 15197:2003), resultaron 72 pacientes a los cuales se les aplicó además muestreo aleatorio simple y criterios de exclusión. La glucemia se determinó mediante el método de referencia (RapiglucoTest) y el glucómetro SUMASENSOR SXT.Resultados: los pacientes tenían 58,7 ± 18,3 años; 54,2 por ciento eran mujeres; 51,4 por ciento diabéticos y el 70,8 por ciento no estaban en ayunas. El error medio absoluto fue 9,5 ± 8,07 por ciento. El desacuerdo entre métodos fue del 4,8 por ciento. El sesgo y la precisión fueron 0,40 mmol/L y ± 0,65 mmol/l, respectivamente. El 94,4 por ciento de valores estuvieron entre los límites de concordancia de ± 1,96 desviaciones Standard (método de Bland-Altman). Resultaron altos los coeficientes de correlación intraclase (0,995) y de determinación (0,98). No contrastaron significativamente las diferencias absolutas según el estado de ayuno o no (p=0,3103).Conclusiones:el grado de desacuerdo se ajustó al valor aceptado por las normas ISO 15197. El análisis global demuestra que este glucómetro es suficientemente exacto y preciso para su uso en Cuerpo de Guardia, independientemente del estado de ayuno o no(AU)
ABSTRACT
Introduction: measurement of a medical parameter through different methods demands assessment of the agreement between them.Objective: to determine the disagreement between glucose levels obtained by a glucometer and the customary method of laboratory, in the emergency room.Methods: an observational study was performed in patients attended at emergency room of Vladimir I. Lenin Hospital, in Holguín, Cuba, with requested determination of blood glucose levels. The study was carried out during March, 2013. The sample size was calculated taking into account a 5 percent of accepted disagreement by the International Organization of Standardization criteria (ISO 15197:2003), being 72 the obtained number. A simple random sampling and exclusion criteria were also applied. Glucose blood levels were assessed using RapiglucoTest reference method and a glucometer SUMASENSOR SXT.Results: patients were 58.7± 18.3 years, 54.2 percent were female, 51.4% diabetics, and 70.8 percent nonfasting. Mean absolute relative error was 9.5± 8.07 percent. There was 4.8 por ciento of disagreement between methods. Skew and precision were 0.40 mmol/L and ± 0.65 mmol/l, respectively. 94.4 percent of values were between the limits of 1.96 standard deviation (Bland-Altman method). Both Intraclass coefficient correlation (0.995) and determination coefficient (0.98) reached high values. No significant disparity between absolute differences were assessed depending upon fasting state (p=0.3103).Conclusions:the disagreement between methods corresponded to the admissible threshold stablished by ISO criteria. This and the rest of the analysis indicate that this glucometer is both accurate and precise for its intended use in the emergency room setting, even in nonfasting individuals(AU)
Asunto(s)
Palabras clave
Texto completo: 1 Colección: 06-national / CU Base de datos: CUMED Asunto principal: Glucemia / Índice Glucémico / Servicios Médicos de Urgencia Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Female / Humans / Male Idioma: Es Revista: CCM Año: 2014 Tipo del documento: Article
Texto completo: 1 Colección: 06-national / CU Base de datos: CUMED Asunto principal: Glucemia / Índice Glucémico / Servicios Médicos de Urgencia Tipo de estudio: Clinical_trials / Observational_studies Límite: Adult / Female / Humans / Male Idioma: Es Revista: CCM Año: 2014 Tipo del documento: Article