RESUMEN

Objetivo:

medir la validez de constructo de la escala NEI-VFQ-25 en una población colombiana con enfermedad ocular crónica.

Métodos:

se evaluó la tecnología diagnóstica mediante el Modelo Rasch. Se calculó una muestra para garantizar la estabilidad en la calibración de los ítems. Se incluyeron hombres y mujeres de 40-70 años de edad, con enfermedad ocular crónica bilateral, a quienes, previo consentimiento informado, se les aplicó, vía telefónica, la escala NEI-VFQ-25.

Resultados:

se entrevistaron 206 personas con edad promedio de 58,1 años, quienes presentaban glaucoma (21,7 por ciento), catarata (36,9 por ciento) o algún tipo de retinopatía (35,4 por ciento). Se eliminaron dos ítems del cuestionario original, por funcionamiento diferencial (DIF) y cuatro por ajuste al modelo. Se estandarizaron todas las preguntas a tres opciones de respuesta, y quedó una escala conformada por 17 ítems que cumplía con los criterios de validez de constructo.

Conclusión:

la escala NEI-VFQ mostró validez sustantiva, de contenido, generalización y estructural, en personas de 40 a 70 años con diagnóstico de glaucoma, catarata y retinopatía(AU)
ABSTRACT

Objective:

to measure the validity of the NEI-VFQ-25 scale construct in a Colombian population with chronic ocular disease.

Methods:

the diagnostic technology was evaluated through Rasch model. A sample was estimated to guarantee the stability of item gaging. Forty to seventy years-old men and women, with chronic bilateral ocular disease, participated. After informed consent, they were applied the NEI-VFQ-25 scale by phone.

Results:

two hundred and six persons aged 58.1 years as average, who presented with glaucoma (21.7 percent), cataract (36.9 percent) or some type of retinopathy (35.4 percent). Two items were taken out of the original questionnaire because of differential functioning and four items due to model adjustment. All the questions were then standardized to have three response options, and finally the scale was made up of 17 items which met the validity criteria for construct.

Conclusions:

NEI-VFQ scale showed substantial, content, generalization and structural validity for application in 40 to 70 years old people with diagnosis of glaucoma, cataract and retinopathy(AU)
Asunto(s)
Palabras clave
Texto completo: 1 Colección: 06-national / CU Base de datos: CUMED Asunto principal: Calidad de Vida / Evaluación de la Tecnología Biomédica / Reproducibilidad de los Resultados / Oftalmopatías Tipo de estudio: Diagnostic_studies / Health_technology_assessment / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Aged / Female / Humans / Male País/Región como asunto: America do sul / Colombia Idioma: Es Revista: Rev. cuba. oftalmol Año: 2017 Tipo del documento: Article
Texto completo: 1 Colección: 06-national / CU Base de datos: CUMED Asunto principal: Calidad de Vida / Evaluación de la Tecnología Biomédica / Reproducibilidad de los Resultados / Oftalmopatías Tipo de estudio: Diagnostic_studies / Health_technology_assessment / Prognostic_studies Aspecto: Patient_preference Límite: Adult / Aged / Female / Humans / Male País/Región como asunto: America do sul / Colombia Idioma: Es Revista: Rev. cuba. oftalmol Año: 2017 Tipo del documento: Article