Your browser doesn't support javascript.
loading
Evaluación de la estadificación inicial y la respuesta final al tratamiento de los pacientes con linfoma difuso de célula grande B con la tomografía computarizada de 64 detectores frente a la 18FDG tomografía por emisión de positrones/tomografía computarizada / Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment
Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos.
Afiliación
  • Gómez León, Nieves; Hospital Universitario de la Princesa. Servicio de Radiología. Madrid. España
  • Vega, Gema; Hospital Universitario de la Princesa. Servicio de Radiología. Madrid. España
  • Rodríguez-Vigil Junco, Beatriz; Hospital Universitario de Álava. Resonancia magnética Osatek. Vitoria. España
  • Suevos Ballesteros, Carlos; Universidad Autónoma de Madrid. Madrid. España
Med. clín (Ed. impr.) ; 151(7): 255-264, oct. 2018. ilus, tab, graf
Article en Es | IBECS | ID: ibc-173945
Biblioteca responsable: ES1.1
Ubicación: BNCS
RESUMEN
Fundamento y

objetivos:

Comparar prospectivamente la exactitud diagnóstica de la tomografía computarizada de 64 detectores (TCMD64) y la tomografía por emisión de positrones/tomografía computarizada (18FDG PET/TC) con contraste intravenoso en pacientes con linfoma difuso de células grandes B (LDCGB) en la estadificación inicial y en la evaluación de la respuesta al final del tratamiento. Material y

métodos:

Ensayo clínico controlado multicéntrico que incluyó 72 pacientes de 5 hospitales de la Comunidad de Madrid entre enero de 2012 y junio de 2015, aleatorizados de forma ciega a una diferente prueba de imagen inicial y final, 36 a 18FDG PET/TC y 36 a TCMD64. Un médico nuclear y un radiólogo interpretaron la 18FDG PET/TC de manera independiente, llegando a un consenso post-hoc. Por otro lado, un radiólogo ajeno interpretó la TCMD64 por separado. El patrón de referencia incluyó datos clínicos, pruebas complementarias y seguimiento. El Comité Ético de cada hospital aprobó el estudio y los sujetos firmaron su consentimiento por escrito.

Resultados:

Se observó buena concordancia de ambas pruebas diagnósticas con el patrón de referencia en la estadificación inicial (18FDG PET/CT [k=0,5] y TCMD64 [k=0,6]), existiendo solo buena concordancia en la evaluación de la respuesta al final del tratamiento con la 18FDG PET/TC (k=0,7).

Conclusión:

En la estadificación inicial de pacientes con LDCGB existe un grado de acuerdo satisfactorio de la 18FDG PET/TC y la TCMD64 con el patrón de referencia, mientras que en la evaluación de la respuesta al final del tratamiento la 18FDG PET/TC es superior a la TCMD64
ABSTRACT
Background and

objectives:

To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Material and

methods:

Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres’ ethics committees and written informed consent was obtained from all the participants.

Results:

A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7).

Conclusion:

In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment
Asunto(s)
Buscar en Google
Colección: 06-national / ES Base de datos: IBECS Asunto principal: Linfoma de Células B Grandes Difuso / Tomografía Computarizada Multidetector / Tomografía Computarizada por Tomografía de Emisión de Positrones / Estadificación de Neoplasias Tipo de estudio: Clinical_trials / Observational_studies Aspecto: Ethics Límite: Female / Humans / Male Idioma: Es Revista: Med. clín (Ed. impr.) Año: 2018 Tipo del documento: Article
Buscar en Google
Colección: 06-national / ES Base de datos: IBECS Asunto principal: Linfoma de Células B Grandes Difuso / Tomografía Computarizada Multidetector / Tomografía Computarizada por Tomografía de Emisión de Positrones / Estadificación de Neoplasias Tipo de estudio: Clinical_trials / Observational_studies Aspecto: Ethics Límite: Female / Humans / Male Idioma: Es Revista: Med. clín (Ed. impr.) Año: 2018 Tipo del documento: Article