Influence of angle Kappa on the optimal intraocular orientation of asymmetric multifocal intraocular lenses
Bonaque-González, Sergio; Jaskulski, Matt T; Carmona-Ballester, David; Pareja-Ríos, Alicia; Trujillo-Sevilla, Juan M.
Afiliación
  • Bonaque-González, Sergio; Wooptix S.L. San Cristobal de La Laguna. Spian
  • Jaskulski, Matt T; University of Murcia. Murcia. Spain
  • Carmona-Ballester, David; University of La Laguna. Faculty of Physics. Department of Industrial Engineering. San Cristobal de La Laguna. Spain
  • Pareja-Ríos, Alicia; Hospital Universitario de Canarias. Santa Cruz de Tenerife. Spain
  • Trujillo-Sevilla, Juan M; Wooptix S.L. San Cristobal de La Laguna. Spian
J. optom. (Internet) ; 14(1): 78-85, ene.-mar. 2021. ilus, tab, graf
Article en En | IBECS | ID: ibc-200295
Biblioteca responsable: ES1.1
Ubicación: BNCS
ABSTRACT
PURPOSE: to evaluate the effects of kappa angle and intraocular orientation on the theoretical performance of asymmetric multifocal intraocular lenses (MIOL). METHODS: For a total of 21 corneal aberrations, a computational analysis simulated the implantation of a computationally designed MIOL. An image quality parameter (IQ) (visually modulated transfer function metric) was calculated for a 5.0-mm pupil and for three conditions: distance, intermediate, and near vision. The procedure was repeated for each eye after a rotation of the MIOL with respect to the cornea from 0º to 360º in 5º steps. Kappa angles from 0 to 900 microns, in 150 microns steps, combined with two two variants of MIOL centration were tested: in the corneal apex or in the center of the entrance pupil. A p-value ≤ 0.05 was considered significant. RESULTS: There were statistically significant differences of the IQ depending of the intraocular orientation of the MIOL. If kappa angle was increased, there was a statistically significant decrease of the IQ. The IQ maintained stable when the optimal intraocular orientation was re-calculated for each kappa angle. In general, the inter-variability of the results between subjects was very high. There were no strong evidences supporting that there exists a preferable centration point. CONCLUSIONS: Our results suggest that kappa angle theoretically affects significantly the performance of asymmetric MIOL implantation. However, its negative effect can be compensated if a customized intraocular orientation is calculated taking into account the presence of the kappa angle
RESUMEN
No disponible
Asunto(s)

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Aberración de Frente de Onda Corneal / Modelación Específica para el Paciente / Lentes Intraoculares Multifocales Límite: Aged / Female / Humans / Male Idioma: En Revista: J. optom. (Internet) Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Aberración de Frente de Onda Corneal / Modelación Específica para el Paciente / Lentes Intraoculares Multifocales Límite: Aged / Female / Humans / Male Idioma: En Revista: J. optom. (Internet) Año: 2021 Tipo del documento: Article