Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT
Tañá-Rivero, Pedro; Ruiz-Mesa, Ramón; Aguilar-Córcoles, Salvador; Tello-Elordi, Cristina; Ramos-Alzamora, María; Montés-Micó, Robert.
Afiliación
  • Tañá-Rivero, Pedro; Oftalvist Clinic. Alicante. Spain
  • Ruiz-Mesa, Ramón; Oftalvist Clinic. Alicante. Spain
  • Aguilar-Córcoles, Salvador; Oftalvist Clinic. Alicante. Spain
  • Tello-Elordi, Cristina; Oftalvist Clinic. Alicante. Spain
  • Ramos-Alzamora, María; Oftalvist Clinic. Alicante. Spain
  • Montés-Micó, Robert; Oftalvist Clinic. University of Valencia. Valencia. Spain
J. optom. (Internet) ; 15(1): 1-12, January-March 2022. tab, graf
Article en En | IBECS | ID: ibc-204384
Biblioteca responsable: ES1.1
Ubicación: ES15.1 - BNCS
ABSTRACT
Purpose: To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT).Methods: We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance.Results: Mean LV was 0.26 ± 0.23 mm (ranging from -0.24 to 0.78 mm). Data analysis revealed a statistically significant negative correlation between LV and ACD (R=-0.80, p < 0.001), AL (R = -0.36, p = 0.002), and ACV (R = -0.68, p < 0.001), and a positive correlation between LV and LT (R = 0.67, p < 0.001), and age (R = 0.53, p < 0.001). In contrast, no statistically significant correlation was found between LV and WTW (R=-0.17, p = 0.15), CCT (R = 0.11, p = 0.36) or STS (R=-0.10, p = 0.41).Conclusions: Taking into account our findings about intra-parameter correlation levels, we believe that LV should be measured and analyzed together with other ocular parameters in clinical routine practice both for diagnosis and for some refractive surgeries. (AU)
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Biometría / Longitud Axial del Ojo / Cápsula del Cristalino / Cámara Anterior Límite: Adult / Humans Idioma: En Revista: J. optom. (Internet) Año: 2022 Tipo del documento: Article