Your browser doesn't support javascript.
loading
Tratamiento a distancia de la insuficiencia cardiaca mediante el algoritmo HeartLogic. Registro RE-HEART / Remote heart failure management using the HeartLogic algorithm. RE-HEART registry
de Juan Bagudá, J; Gavira Gómez, J. J; Pachón Iglesias, M; Cózar León, R; Escolar Pérez, V; González Fernández, Ó; Rivas Gándara, N; Goirigolzarri Artaza, J; Díaz Molina, B; Macías Gallego, A.
Afiliación
  • de Juan Bagudá, J; Instituto de Investigación Sanitaria Hospital 12 de Octubre (imas12). Hospital Universitario 12 de Octubre. Servicio de Cardiología. Madrid. España
  • Gavira Gómez, J. J; Clínica Universidad de Navarra. Servicio de Cardiología. Navarra. España
  • Pachón Iglesias, M; Complejo Hospitalario Universitario de Toledo. Servicio de Cardiología. Toledo. España
  • Cózar León, R; Hospital Universitario Virgen Macarena. Servicio de Cardiología. Sevilla. España
  • Escolar Pérez, V; Hospital Universitario de Basurto. Servicio de Cardiología. Vizcaya. España
  • González Fernández, Ó; Hospital Universitario La Paz. Servicio de Cardiología. España. Madrid
  • Rivas Gándara, N; Hospital Universitario Vall d’Hebron. Servicio de Cardiología. Barcelona. España
  • Goirigolzarri Artaza, J; Hospital Universitario Clínico San Carlos. Servicio de Cardiología. Madrid. España
  • Díaz Molina, B; Hospital Universitario Central de Asturias. Servicio de Cardiología. Asturias. España
  • Macías Gallego, A; Talavera de la Reina. Servicio de Cardiología. Toledo. España
Rev. esp. cardiol. (Ed. impr.) ; 75(9): 710-717, sept. 2022. tab
Artículo en Español | IBECS | ID: ibc-208223
Biblioteca responsable: ES1.1
Ubicación: ES15.1 - BNCS
RESUMEN
Introducción y objetivos HeartLogic es un algoritmo multiparamétrico incorporado a desfibriladores automáticos implantables (DAI). La alerta asociada predice descompensaciones de insuficiencia cardiaca (IC). Nuestro objetivo es analizar la asociación entre alertas y eventos clínicos bajo un protocolo de seguimiento común en un registro multicéntrico. Métodos Se evaluaron la fase 1 (investigadores ciegos al estado de la alerta) y las fases 2 y 3 (tras la activación de HeartLogic, según práctica local y un protocolo común respectivamente). Resultados Se incluyó a 288 pacientes en 15 centros. En fase 1, tras una media de observación de 10 meses, hubo 73 alertas (0,72 alertas/paciente-año), con 8 hospitalizaciones y 2 visitas a urgencias por IC (0,10 eventos/año-paciente). No hubo hospitalizaciones fuera del periodo de alerta. Las fases activas tuvieron una media de seguimiento de 16 (IC95%, 15-22) meses, con 277 alertas (0,89 alertas/año-paciente); 33 se asociaron con hospitalizaciones o muerte por IC, 46 con descompensaciones menores y 78 con otros eventos. La tasa de alertas inexplicables fue 0,39/año-paciente. Fuera del estado de alerta solo hubo una hospitalización y una descompensación menor. La mayoría de las alertas (el 82% en fase 2 y el 81% en fase 3; p=0,861) se gestionaron a distancia. La mediana de NT-proBNP fue superior en estado de alerta que fuera de él (7.378 frente a 1.210 pg/ml; p <0,001). Conclusiones El índice HeartLogic se asoció con descompensaciones de IC y otros eventos relevantes, con baja tasa de alertas inexplicables. Un protocolo estandarizado permitió detectar y actuar a distancia con seguridad sobre las alertas (AU)
ABSTRACT
Introduction and objectives HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. Methods We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). Results We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). Conclusions The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them (AU)
Asunto(s)


Texto completo: Disponible Colección: Bases de datos nacionales / España Base de datos: IBECS Asunto principal: Algoritmos / Desfibriladores Implantables / Telemonitorización / Insuficiencia Cardíaca Límite: Anciano / Femenino / Humanos / Masculino Idioma: Español Revista: Rev. esp. cardiol. (Ed. impr.) Año: 2022 Tipo del documento: Artículo Institución/País de afiliación: Clínica Universidad de Navarra/España / Complejo Hospitalario Universitario de Toledo/España / Hospital Universitario Central de Asturias/España / Hospital Universitario Clínico San Carlos/España / Hospital Universitario La Paz/Madrid / Hospital Universitario Vall d’Hebron/España / Hospital Universitario Virgen Macarena/España / Hospital Universitario de Basurto/España / Instituto de Investigación Sanitaria Hospital 12 de Octubre (imas12)/España / Talavera de la Reina/España

Texto completo: Disponible Colección: Bases de datos nacionales / España Base de datos: IBECS Asunto principal: Algoritmos / Desfibriladores Implantables / Telemonitorización / Insuficiencia Cardíaca Límite: Anciano / Femenino / Humanos / Masculino Idioma: Español Revista: Rev. esp. cardiol. (Ed. impr.) Año: 2022 Tipo del documento: Artículo Institución/País de afiliación: Clínica Universidad de Navarra/España / Complejo Hospitalario Universitario de Toledo/España / Hospital Universitario Central de Asturias/España / Hospital Universitario Clínico San Carlos/España / Hospital Universitario La Paz/Madrid / Hospital Universitario Vall d’Hebron/España / Hospital Universitario Virgen Macarena/España / Hospital Universitario de Basurto/España / Instituto de Investigación Sanitaria Hospital 12 de Octubre (imas12)/España / Talavera de la Reina/España
...