Your browser doesn't support javascript.
loading
Factors Associated With Asthma Control in 121 Preschool Children
Leiria-Pinto, P; Carreiro-Martins, P; Peralta, I; Marques, J; Finelli, E; Alves, C; Belo, J; Alves, M; Papoila, A. L; Neuparth, N.
Afiliación
  • Leiria-Pinto, P; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Carreiro-Martins, P; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Peralta, I; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Marques, J; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Finelli, E; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Alves, C; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
  • Belo, J; Centro Hospitalar Universitário Cova da Beira. Covilhã. Portugal
  • Alves, M; Hospital Dona Estefânia – CHULC. Centro de Investigação. Lisbon. Portugal
  • Papoila, A. L; NOVA Medical School/Comprehensive Health Research Center (CHRC). Lisbon. Portugal
  • Neuparth, N; Hospital Dona Estefânia – CHULC. Immunoallergology Department. Lisbon. Portugal
J. investig. allergol. clin. immunol ; 31(6): 471-480, 2021. ilus, tab, graf
Article en En | IBECS | ID: ibc-216774
Biblioteca responsable: ES1.1
Ubicación: ES15.1 - BNCS
ABSTRACT

Background:

Data on risk factors for uncontrolled asthma in preschool children are controversial.

Objective:

This study aims to explore the association between clinical and functional parameters and the lack of asthma control in preschool children.

Methods:

Children aged 3-5 years with asthma and healthy controls were recruited. A questionnaire was used to identify potential risk factors for uncontrolled asthma, as defined by the Global INitiative for Asthma criteria. Lung function and bronchial reversibility were evaluated through impulse oscillometry and spirometry. Adjusted odds ratios were estimated based on multivariable generalized additive regression models. The discriminative ability of the models was measured by the area under the receiver operating characteristic curve (AUC).

Results:

The study population comprised 121 children (107 with asthma and 14 healthy controls). Fifty-three patients (50%) had uncontrolled asthma. After adjustment, the variables associated with an increased risk of lack of control were as follows “More than 3 flare-ups in the last 12 months”, “Moderate to severe rhinitis”, and “Relative variation in postbronchodilator FVC and FEV1”. The AUC of the final models that included variation in FVC or FEV1 were 0.82 and 0.81, respectively. The R5-20, R5-20%, and AX z-score values of the healthy group were lower than those of children with asthma.

Conclusion:

In preschool children, clinical and functional parameters are associated with uncontrolled asthma. More studies are needed to confirm the usefulness of impulse oscillometry (AU)
RESUMEN
Antecedentes Existe controversia sobre los factores de riesgo de asma no controlada en niños en edad preescolar.

Objetivo:

Este estudio tiene como objetivo explorar la asociación entre los parámetros clínicos y funcionales y la falta de control del asmaen niños en edad preescolar.

Métodos:

Se reclutaron niños de 3-5 años con asma y controles sanos. Se utilizó un cuestionario para identificar los posibles factores de riesgo de asma no controlada según lo definido por los criterios de la GINA (Global Initiative for Asthma [Iniciativa global para el asma]).La función pulmonar y la reversibilidad bronquial se evaluaron mediante oscilometría de impulsos (IOS) y espirometría. Los odds ratios ajustados (OR) se estimaron en base a modelos de regresión aditiva generalizada multivariable. La capacidad discriminativa de los modelos se midió por el área bajo la curva de características operativas del receptor (AUC).

Resultados:

Se incluyeron 121 niños, 107 de los cuales tenían asma y 14 eran controles sanos. Cincuenta y tres pacientes (50%) tenían asma no controlada. Después del ajuste, las variables asociadas con un mayor riesgo de falta de control fueron "Más de 3 reagudizaciones en los últimos 12 meses", "rinitis moderada a grave"y "variación relativa en FVC y FEV1 después del broncodilatador". El AUC de los modelos finales que incluyeron variación de la FVC o FEV1 fueron 0,82 y 0,81, respectivamente. Los valores de R5-20, R5-20% y AX z-score del grupo sano fueron más bajos que los de los niños con asma.

Conclusión:

En niños en edad preescolar, los parámetros clínicos y funcionales están asociados con el asma no controlada. Se necesitan más estudios para confirmar la utilidad del IOS (AU)
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Asma Límite: Child, preschool / Female / Humans / Male Idioma: En Revista: J. investig. allergol. clin. immunol Año: 2021 Tipo del documento: Article

Texto completo: 1 Colección: 06-national / ES Base de datos: IBECS Asunto principal: Asma Límite: Child, preschool / Female / Humans / Male Idioma: En Revista: J. investig. allergol. clin. immunol Año: 2021 Tipo del documento: Article