Your browser doesn't support javascript.
loading
A continuous fluorescent assay for the determination of plasma and tissue angiotensin I-converting enzyme activity
Alves, M. F; Araujo, M. C; Juliano, M. A; Oliveira, E. M; Krieger, J. E; Casarini, D. E; Juliano, L; Carmona, A. K.
Afiliación
  • Alves, M. F; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Biofísica. São Paulo. BR
  • Araujo, M. C; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Biofísica. São Paulo. BR
  • Juliano, M. A; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Biofísica. São Paulo. BR
  • Oliveira, E. M; Universidade de São Paulo. Escola de Educação Física e Esporte. Laboratório de Bioquímica da Atividade Motora. São Paulo. BR
  • Krieger, J. E; Universidade de São Paulo. Faculdade de Medicina. Instituto do Coração. Laboratório de Genética e Cardiologia Molecular. São Paulo. BR
  • Casarini, D. E; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Medicina. Disciplina de Nefrologia. São Paulo. BR
  • Juliano, L; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Biofísica. São Paulo. BR
  • Carmona, A. K; Universidade Federal de São Paulo. Escola Paulista de Medicina. Departamento de Biofísica. São Paulo. BR
Braz. j. med. biol. res ; 38(6): 861-868, June 2005. tab, graf
Article en En | LILACS | ID: lil-402675
Biblioteca responsable: BR1.1
ABSTRACT
A continuous assay using internally quenched fluorescent peptides with the general sequence Abz-peptidyl-(Dnp)P-OH (Abz = ortho-aminobenzoic acid; Dnp = 2,4-dinitrophenyl) was optimized for the measurement of angiotensin I-converting enzyme (ACE) in human plasma and rat tissues. Abz-FRK(Dnp)P-OH, which was cleaved at the Arg-Lys bond by ACE, was used for the enzyme evaluation in human plasma. Enzymatic activity was monitored by continuous recording of the fluorescence (lambdaex = 320 nm and lambdaem = 420 nm) at 37°C, in 0.1 M Tris-HCl buffer, pH 7.0, with 50 mM NaCl and 10 æM ZnCl2. The assays can be performed directly in the cuvette of the fluorimeter and the hydrolysis followed for 5 to 10 min. ACE measurements in the plasma of 80 healthy patients with Hip-His-Leu and with Abz-FRK(Dnp)P-OH correlated closely (r = 0.90, P < 0.001). The specificity of the assay was demonstrated by the complete inhibition of hydrolysis by 0.5 æM lisinopril or captopril. Abz-FRK(Dnp)P-OH cleavage by ACE was monitored in rat lung, kidney, heart, and liver homogenates in the presence of a cocktail of inhibitors containing trans-epoxy-succinyl-L-leucylamido-(4-guanido)-butene, pepstatin, phenyl-methylsulfonyl fluoride, N-tosyl-L-phenylalanyl-chloromethyl ketone, and N-tosyl-lysyl-chloromethyl ketone to prevent undesirable hydrolysis. ACE activity in lung, heart and kidney homogenates, but not in liver homogenates, was completely abolished by 0.5 æM lisinopril or captopril. The advantages of the method are the procedural simplicity and the high sensitivity providing a rapid assay for ACE determinations.
Asunto(s)
Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Peptidil-Dipeptidasa A / Fluorometría Límite: Animals / Humans Idioma: En Revista: Braz. j. med. biol. res Asunto de la revista: BIOLOGIA / MEDICINA Año: 2005 Tipo del documento: Article País de afiliación: Brasil
Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Peptidil-Dipeptidasa A / Fluorometría Límite: Animals / Humans Idioma: En Revista: Braz. j. med. biol. res Asunto de la revista: BIOLOGIA / MEDICINA Año: 2005 Tipo del documento: Article País de afiliación: Brasil