Endoscopic ultrasound guided fine-needle aspiration core biopsy: comparison between an automatic biopsy device and two conventional needle systems / Biopsia tecidual con aguja fina guiada por ultrasonido endoscópico: comparación entre un dispositivo automático de la biopsia y dos sistemas de agujas convencionales
Acta gastroenterol. latinoam
; Acta gastroenterol. latinoam;38(2): 105-115, jun. 2008. ilus, tab
Article
en En
| LILACS
| ID: lil-503619
Biblioteca responsable:
BR1.1
ABSTRACT
BACKGROUND:
endoscopic ultrasound guided fine-needle aspiration (EUS-FNA) allows cytologic and/or histologic diagnosis of lesions within or adjacent to the gastrointestinal tract. However, the amount of tissue obtained with a regular 22 gauge needle is not always satisfactory. With the development of a needle XNA-10J-KB (Shot-Gun) that resembles the automatic liver biopsy needle, it is expected that significant samples be obtained more frequently (core biopsy), optimizing histological analysis.OBJECTIVE:
to compare samples obtained with EUS-FNA using 3 different needle systems GIP, NA-10J-1 and Shot-Gun.METHODS:
19 patients underwent EUS-FNA for diagnosis (5) or tumor staging (14). Mean age was 58.9 years (range 27-82), being 50% men. All patients were submitted to EUS-FNA with the 3 needle models. The Shot-Gun model was "shot" when its tip was near the target inside the lesion, followed by aspiration. Samples were submitted for cytologic and histologic examination.RESULTS:
mean lesion size was 3.0 cm (range 0.8-5.5 cm). Final diagnoses were made after surgery or intra-operative biopsy 13 pancreatic tumors (12 adenocarcinomas and 1 neuroendocrine tumor), 4 chronic pancreatitis, 1 acute pancreatitis, and 1 cholangiocarcinoma. Specimens adequate for cytologic diagnosis were obtained in 13/19 (68. 4%) patients using GIP model, in 14/19 (73.7%) with NA10J-1 model, and in 17/19 (89.5%) with ShotGun, model (p=0.039). Histologic analysis was possible in 10/19 (52.6%) patients using the GIP model, in 14/19 (73.7%) with NA10J-1, and in 17/19 (89.5%) with Shot-Gun, model (p=0.005). Adequate samples for cytologic or histologic assessment in 16/19 (84.2%) patients using the GIP model, in 17/19 (89.5%) with NA10J-1, and in 18/19 (94.7%) with Shot-Gun, model (p=0.223). In two cases biopsies were negative due to very hard tumors.CONCLUSION:
the Shot-Gun needle obtained better samples for histological diagnosis than NA10J-1 needle and GIP.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
Asunto principal:
Neoplasias Pancreáticas
/
Pancreatitis
/
Endosonografía
/
Biopsia con Aguja Fina
Tipo de estudio:
Diagnostic_studies
/
Prognostic_studies
Límite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Acta gastroenterol. latinoam
Asunto de la revista:
GASTROENTEROLOGIA
Año:
2008
Tipo del documento:
Article
País de afiliación:
Brasil
Pais de publicación:
Argentina