Avaliação de Sistema de Leitura Portátil (SLP) para baixa visão desenvolvido no Brasil / Evaluation of System Portable Reading (SPR) for low vision developed in Brazil
Santos, Vagner Rogério dos; Lima, Eliana Cunha; Berezovsky, Adriana; Schor, Paulo; Uras, Ricardo; Belfort Junior, Rubens.
Afiliación
  • Santos, Vagner Rogério dos; Universidade Federal de São Paulo. São Paulo. BR
  • Lima, Eliana Cunha; Fundação Dorina Nowill para Cegos. Setor de Reabilitação Visual. São Paulo. BR
  • Berezovsky, Adriana; Universidade Federal de São Paulo. Departamento de Oftalmologia. São Paulo. BR
  • Schor, Paulo; Universidade Federal de São Paulo. Departamento de Oftalmologia. Setor de Bioengenharia. São Paulo. BR
  • Uras, Ricardo; Universidade Federal de São Paulo. Departamento de Oftalmologia. São Paulo. BR
  • Belfort Junior, Rubens; Universidade Federal de São Paulo. Departamento de Oftalmologia. São Paulo. BR
Rev. bras. oftalmol ; 68(5): 259-263, set.-out. 2009. ilus, tab
Artículo en Portugués | LILACS | ID: lil-536426
Biblioteca responsable: BR1.2
RESUMO
OBJETIVO: A proposta deste estudo é avaliar a eficácia e eficiência em uma série de casos do protótipo de um equipamento nacional de magnificação para leitura. MÉTODOS: Participaram deste estudo 30 pacientes na faixa etária entre 9 e 80 anos (17 do sexo masculino). Foi desenvolvido um aparelho portátil, patenteado pela UNIFESP (PI#020050145260), com um sistema de captura de imagens acoplado a um monitor de 5,6 polegadas proporcionando um aumento de 15 X. Foram analisadas a eficácia da acuidade visual e a eficiência de leitura após a utilização do protótipo proposto. RESULTADOS: Seis pacientes (20 por cento) apresentaram AV 8M, 12 pacientes (40 por cento) apresentaram AV 6M, 7 pacientes (23,3 por cento) apresentaram 5 M, 5 pacientes (16,7 por cento) apresentaram 4M. A média de acuidade visual antes da utilização do SLP medida pela tabela LHNV-1 logMAR foi de 5,75M e após a utilização 100 por cento dos pacientes atingiram a eficácia de AV J1. CONCLUSÃO: O protótipo do SLP mostrou-se um recurso alternativo no processo de inclusão social das pessoas com baixa visão com diferentes níveis de resíduo visual. Também pode proporcionar incentivo psicológico, permitir conforto, mobilidade e independência àqueles que necessitam de uma leitura mais prolongada e maior distância de trabalho.
ABSTRACT
PURPOSE: The proposal of this study is to test and to validate as the effectiveness and efficiency in a series of cases the prototype of a national equipment of magnification to reading. METHODS: A recently developed of equipment of magnification (patent pending Brazilian Institutte of Industrial Property # 020050145260) was tested in a group of 30 patients (age range 9 to 80 years, 17 males). A portable apparatus was developed with a system of capture of images coupled with a 5,6 inch monitor, providing an increase of 15 X. The effectiveness of the visual acuity and the reading efficiency were analyzed after the use of the proposed prototype. RESULTS: Six patients (20 percent) presented AV 8M, 12 patients (40 percent) presented AV 6,0M, 7 patients (23.3 percent) presented AV 5M, 5 patients (16.7 percent) presented 4M. The average of visual acuity before the utilization of SPR measured by LHNV-1 logMAR chart was 5,75M. After the use of LHNV-1 logMAR chart, 100 percent (one hundred percent) of the patients reached the efficacy of AV J1. CONCLUSION: The prototype of SPR is an alternative resource in the social inclusion process of low vision patients with different levels of visual residue. It demonstrates psychological incentive, allows comfort, mobility and independence to those who need a more extended lecture and more distance of work.
Asunto(s)

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Asunto principal: Calidad de Vida / Lectura / Ingeniería Biomédica / Baja Visión / Diseño de Equipo Aspecto: Preferencia del paciente País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Rev. bras. oftalmol Asunto de la revista: Oftalmología Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Fundação Dorina Nowill para Cegos/BR / Universidade Federal de São Paulo/BR
Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS Asunto principal: Calidad de Vida / Lectura / Ingeniería Biomédica / Baja Visión / Diseño de Equipo Aspecto: Preferencia del paciente País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Rev. bras. oftalmol Asunto de la revista: Oftalmología Año: 2009 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Fundação Dorina Nowill para Cegos/BR / Universidade Federal de São Paulo/BR
...