Correlación entre índices de bioimpedancia eléctrica y score Apache II en pacientes con shock séptico / Correlation between indexes of electrical bioimpedance and Apache II score in patients with septic shock
Rev. méd. hered
; 21(3): 111-117, jul.-sept. 2010. tab, graf
Article
en Es
| LILACS, LIPECS
| ID: lil-575453
Biblioteca responsable:
PE1.1
RESUMEN
Objetivo:
Determinar la correlación entre diversos índices de bioimpedancia eléctrica (IBE) y el score APACHE II (sAII) en pacientes con shock séptico. Material ymétodos:
Se incluyeron 30 pacientes >14 años con shock séptico de la unidad de cuidados intensivos (UCI) adultos del Hospital Nacional Cayetano Heredia-Perú a quienes se calculó el (sAII) y se midió el ángulo de fase, índice de impedancia y relación LIC/LEC, correlacionándolos posteriormente mediante Pearson y regresión lineal múltiple.Resultados:
El 60% fueron varones, la edad promedio fue 60 ± 20,92 años, talla 1,61 ± 0,06m, peso 65,46 ± 8,7 Kg. y tiempo de ingreso a UCI 8,4 ± 5,99 horas. El 86,6% requirió ventilación mecánica, el foco infeccioso más frecuente fue respiratorio (63,3%). El promedio del sAII fue 18,83 ± 9,23, la permanencia en UCI 8,4 ± 5,99 días y la letalidad al mes 50%. Solamente se encontró correlación negativa con significancia estadística (r = -0,46; p = 0,01) entre el ángulo de fase (AF) y el (sAII). Ni el índice de impedancia ni la relación LIC/LEC tuvieron correlación significativa. El mejor predictor de mortalidad fue el AF todos los que fallecieron tuvieron un AF<6grados (promedio 3,67 ± 0,63), p<0,05.Conclusiones:
Únicamente el AF se correlacionó con el score (sAII) y fue el índice que mejor predijo mortalidad en pacientes con shock séptico, siendo superior al score APACHE II (sAII).ABSTRACT
Objective:
To determine the correlation between various indexes of bioelectrical impedance (IBE) and APACHE II score (sAII) in patients with septic shock. Material andmethods:
We included 30 patients > 14 years old with septic shock admitted to the Adults intensive care unit (ICU) at the Hospital Nacional Cayetano Heredia û Peru. The (sAII) was calculated and various IBE parameters were measured (phase angle, impedance index and relationship ICF/ECF). Correlations were calculated by multiple linear regression and Pearson.Results:
60% were male, mean age was 60 ± 20.92 years, height 161 ± 6 cm, weight 65.46 ± 8.7 kg and time of admission ICU was 8.4 ± 5.99 hours. 86.6% required mechanical ventilation, the most common infection was respiratory in origin (63.3%). The mean sAII was 18.8 ± 9.2, ICU stay was 8.4 ± 5.99 days and mortality was 50% per month. We only found a statistically significant negative correlation (r = - 0.46, p = 0.01) between the phase angle (FA) and (sAII). Neither the impedance index nor the relationship ICF/ECF had significant correlation. The best predictor of mortality was FA those who died had an FA <6 degrees (average 3.67 ± 0.63), p <0.05.Conclusions:
Only FA correlated with the score (sAII) and was the index that best predicted mortality in patients with septic shock, exceeding the APACHE II score (sAII).
Texto completo:
1
Colección:
01-internacional
Base de datos:
LILACS
/
LIPECS
Asunto principal:
Choque Séptico
/
Impedancia Eléctrica
/
APACHE
Tipo de estudio:
Prognostic_studies
Límite:
Adolescent
/
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
Idioma:
Es
Revista:
Rev. méd. hered
Asunto de la revista:
MEDICINA
Año:
2010
Tipo del documento:
Article
País de afiliación:
Perú
Pais de publicación:
Perú