Your browser doesn't support javascript.
loading
Aplicabilidade do indice adiposidade corporal na estimativa do percentual de gordura de jovens mulheres brasileiras / Applicability of body adiposity index in estimating body fat of young brazilian women / Aplicabilidad del indice de adiposidad corporal en la estimativa del porcentual de grasa de jovenes mujeres brasilenas
Dias, Jennifer; Avila, Marcia de; Damasceno, Vinicius de Oliveira; Goncalves, Reginaldo; Barbosa, Fernando Policarpo; Lamounier, Joel Alves; Vianna, Jeferson Macedo.
Afiliación
  • Dias, Jennifer; Universidade Federal de Vicosa. Vicosa. BR
  • Avila, Marcia de; Universidade Federal de Vicosa. Vicosa. BR
  • Damasceno, Vinicius de Oliveira; Universidade Federal de Vicosa. Vicosa. BR
  • Goncalves, Reginaldo; Universidade Federal de Vicosa. Vicosa. BR
  • Barbosa, Fernando Policarpo; Universidade Federal de Vicosa. Vicosa. BR
  • Lamounier, Joel Alves; Universidade Federal de Vicosa. Vicosa. BR
  • Vianna, Jeferson Macedo; Universidade Federal de Vicosa. Vicosa. BR
Rev. bras. med. esporte ; 20(1): 17-20, Jan-Feb/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-704721
Biblioteca responsable: BR1.1
RESUMO

INTRODUÇÃO:

A estimativa da composição corporal é um campo de estudo importante no prognóstico e diagnóstico de enfermidades degenerativas.

OBJETIVO:

Analisar a aplicabilidade do Índice de adiposidade corporal (IAC) e o método de dobras cutâneas.

MÉTODOS:

A amostra foi constituída por 19 adultas jovens com média de idade 24,53 ± 2,65 anos, submetidas à avaliação antropométrica (circunferências e dobras cutâneas) e absorsiometria por dupla emissão de raio X (DXA). Os valores estimados foram comparados ao valor de referência por meio do teste t pareado e pela análise do nível de associação entre os métodos pela correlação de Pearson; o nível de significância foi p < 0,05.

RESULTADOS:

Não apontaram diferenças significativas entre o percentual de gordura estimado pelo IAC e os valores de referência, porém, tiveram nível de associação moderado (r = 0,627). No entanto, o método de dobras cutâneas apresentou diferença estatística significante (p > 0,05) com nível de associação forte (r = 0,879).

CONCLUSÃO:

Embora o IAC não apresente diferença para os valores estimados, fica evidente a necessidade de mais estudos sobre a aplicabilidade do método na população brasileira. .
ABSTRACT

INTRODUCTION:

The estimation of body composition is an important study field in the prognosis and diagnosis of degenerative diseases.

OBJECTIVE:

To analyze the applicability of the Body Adiposity Index (BAI) and the skinfold thickness method.

METHODS:

The sample consisted of 19 young adult women with a mean age 24.53 ± 2.65 years, who underwent anthropometric measurements (circumferences and skinfold thickness) and dual energy X-ray absorptiometry (DEXA). The estimated values were compared to the reference value by using the paired t test and by analysis of the level of association between the methods through the Pearson correlation. The level of significance was p<0.05.

RESULTS:

Showed no significant differences between the fat percentage estimated by the BAI and the reference values, however had moderate level of association (r=0.627). Nevertheless, the skinfold thickness method showed statistically significant difference (p>0.05) with a strong association level (r = 0.879).

CONCLUSION:

Although the BAI does not show difference to the estimated values, it is clear that further studies on the applicability of the method in the Brazilian population are necessary. .
RESUMEN

INTRODUCCIÓN:

La estimativa de la composición corporal es un campo de estudio importante en el pronóstico y diagnóstico de enfermedades degenerativas.

OBJETIVO:

Analizar la aplicabilidad del Índice de Adiposidad Corporal (IAC) y el método de pliegues cutáneos.

MÉTODOS:

La muestra fue constituida por 19 adultas jóvenes con promedio de edad de 24,53 ± 2,65 años, sometidas a evaluación antropométrica (circunferencias y pliegues cutáneos) y absorciometría por doble emisión de rayo X (DXA). Los valores estimados fueron comparados al valor de referencia por medio del test t pareado y por el análisis del nivel de asociación entre los métodos por la correlación de Pearson; el nivel de significancia fue de p < 0,05.

RESULTADOS:

No apuntaron diferencias significativas entre el porcentual de grasa estimado por el IAC y los valores de referencia, no obstante, tuvieron nivel de asociación moderado (r = 0,627). Por otro lado, el método de pliegues cutáneos presentó diferencia estadística significativa (p > 0,05) con nivel de asociación fuerte (r = 0,879).

CONCLUSIÓN:

Aunque el IAC no presente diferencia para los valores estimados, queda evidente la necesidad de más estudios sobre la aplicabilidad del método en la población brasileña. .


Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Vicosa/BR

Texto completo: Disponible Colección: Bases de datos internacionales Base de datos: LILACS País/Región como asunto: America del Sur / Brasil Idioma: Portugués Revista: Rev. bras. med. esporte Asunto de la revista: Medicina Deportiva Año: 2014 Tipo del documento: Artículo País de afiliación: Brasil Institución/País de afiliación: Universidade Federal de Vicosa/BR
...