Your browser doesn't support javascript.
loading
Increasing diagnostic effectiveness of thyroid nodule evaluation by implementation of cell block preparation in routine US-FNA analysis
Cristo, Ana Patrícia de; Goldstein, Heloísa Folgierini; Faccin, Carlo Sasso; Maia, Ana Luiza; Graudenz, Marcia Silveira.
Afiliación
  • Cristo, Ana Patrícia de; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Goldstein, Heloísa Folgierini; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Faccin, Carlo Sasso; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Maia, Ana Luiza; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Graudenz, Marcia Silveira; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
Arch. endocrinol. metab. (Online) ; 60(4): 367-373, Aug. 2016. tab, graf
Article en En | LILACS | ID: lil-792940
Biblioteca responsable: BR1.1
ABSTRACT
ABSTRACT Objective Ultrasound-guided fine-needle aspiration (US-FNA) biopsy has proven to be an accurate and efficient tool in thyroid nodule evaluation. We evaluated whether cell block adds to the diagnostic accuracy of US-FNA. Subjects and methods Three hundred twenty-eight consecutive patients underwent US-FNA, cytology and cell block evaluation. Six slides were prepared for each patient and stained by Papanicolaou and Giemsa techniques. The residual hemorrhagic aspirate in the syringe and needle was fixed in 10% formalin and paraffin-embedded (cell block). The histological sections were examined as a complementary diagnostic tool to US-FNA. Results The study population comprised 89% females and the mean age was 57.4 ± 13.7 years. The mean nodule size was 2.3 ± 1.2 cm. US-FNA cytological results were as follows Bethesda I, 17.1% (n = 56); Bethesda II, 61.6% (n = 202); Bethesda III, 9.5% (n = 31); Bethesda IV, 5.8% (n = 19); Bethesda V, 2.4% (n = 8), and Bethesda VI, 3.6% (n = 12). Cell blocks were obtained in 100% of cases and were considered diagnostic in 89.6%. Combined cytological and cell block (cyto-cell block) results were as follows unsatisfactory, 4.3% (n = 14); benign, 72.6% (n = 238); indeterminate, 11.3% (n = 37); follicular lesion, 5.8% (n = 19); suspicious for malignancy, 2.4% (n = 8), and malignant, 3.6% (n = 12). The sensitivity and specificity for cyto-cell block was 100% and 90%, respectively, and the accuracy was 94%. Cyto-cell block analysis reduced the rate of unsatisfactory samples (p < 0.001). Conclusions The cyto-cell block interpretation improved the efficiency of US-FNA. This simple, fast and low-cost technique should be used as an adjunctive test in thyroid nodule evaluation. Arch Endocrinol Metab. 2016;60(4)367-73.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Glándula Tiroides / Nódulo Tiroideo / Adhesión en Parafina / Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico Tipo de estudio: Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: Arch. endocrinol. metab. (Online) Asunto de la revista: ENDOCRINOLOGIA / METABOLISMO Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: LILACS Asunto principal: Glándula Tiroides / Nódulo Tiroideo / Adhesión en Parafina / Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico Tipo de estudio: Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: Arch. endocrinol. metab. (Online) Asunto de la revista: ENDOCRINOLOGIA / METABOLISMO Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil