Your browser doesn't support javascript.
loading
Two hour ambulation after coronary angioplasty and stenting with 6 F guiding catheters and low dose heparin.
Koch, K T; Piek, J J; de Winter, R J; Mulder, K; Schotborgh, C E; Tijssen, J G; Lie, K I.
Afiliación
  • Koch KT; Department of Cardiology, B2-136, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam, Netherlands.
Heart ; 81(1): 53-6, 1999 Jan.
Article en En | MEDLINE | ID: mdl-10220545
OBJECTIVE: To evaluate the feasibility and safety of ambulation of patients two hours after elective coronary angioplasty or stenting, or both. METHODS: Coronary angioplasty and stenting were performed using 6 F guiding catheters by the femoral approach and a standard dose of heparin 5000 IU. There were no angiographic exclusion criteria except for planned atherectomy. Patients given oral anticoagulants or heparin were not eligible. All patients were given aspirin. Patients who underwent stent implantation also received ticlopidine 250 mg daily. The arterial sheath was removed immediately after the procedure. Haemostasis was achieved by manual compression and maintained with an inguinal compression bandage. Early ambulation was attempted after two hours of supine bed rest following removal of the bandage. MAIN OUTCOME MEASURES: The incidence of bleeding at or during ambulation requiring compression and additional bed rest, and puncture site complications documented 48 hours after the procedure. RESULTS: 300 of 359 consecutive eligible patients were included for two hour ambulation. Stent implantation was performed in 32% of the procedures. The mean (SD) time to haemostasis was 9.6 (3.2) minutes. Bleeding at ambulation occurred in five patients (1.7%), and nine patients (3.0%) reached the secondary end point of haematoma > 5 x 5 cm at 48 hour follow up. All were treated conservatively without further sequelae. There was no late bleeding or vascular complications. CONCLUSION: Ambulation two hours after elective balloon angioplasty or stent implantation with 6 F guiding catheters by the femoral route and low dose heparin is feasible and safe, with a low incidence of puncture site complications. This early ambulation protocol facilitates a short hospital stay.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angioplastia Coronaria con Balón / Stents / Enfermedad Coronaria / Ambulación Precoz Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Asunto de la revista: CARDIOLOGIA Año: 1999 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Angioplastia Coronaria con Balón / Stents / Enfermedad Coronaria / Ambulación Precoz Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Heart Asunto de la revista: CARDIOLOGIA Año: 1999 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido