Indeterminate findings on imaging-guided biopsy: should additional intervention be pursued?
AJR Am J Roentgenol
; 173(2): 461-4, 1999 Aug.
Article
en En
| MEDLINE
| ID: mdl-10430154
ABSTRACT
OBJECTIVE:
Our purpose was to determine the outcome of patients in whom the results of imaging-guided biopsies were indeterminate and to examine factors that may affect outcome. MATERIALS ANDMETHODS:
During a 25-month period, 619 consecutive imaging-guided biopsies (CT, n = 268 [43%]; sonography, n = 351 [57%]) were performed on abdominal lesions. Of these biopsies, findings from 454 biopsies (73%) were positive for malignancy, findings from 21 biopsies (3%) yielded a benign diagnosis, and findings from 15 biopsies (2%) were nondiagnostic. Findings from the remaining 129 biopsies (21%) were considered indeterminate because the pathologic diagnosis revealed benign tissue, inflammation, stromal elements, or atypical cells. The frequency of malignancy in lesions of patients in this indeterminate group was determined.RESULTS:
Thirty-eight of the 129 patients were lost to follow-up. Of the remaining 91 patients, 55 (60%) had true-negative (benign) results, and 36 (40%) had false-negative (malignant) results. A history of malignancy had no significant effect on the true- or false-negative rate (p = .799). However, the guidance technique had a statistically significant effect CT and sonographic guidance yielded 25 (49%) and 11 (28%) false-negative results, respectively (p = .037). The number of needle passes, needle type and gauge, and biopsy site did not have a statistically significant correlation with the false-negative rate. The presence of atypical cells in the cytologic aspirate was highly predictive, with a 71% false-negative rate (p = .008).CONCLUSION:
We found a high incidence of malignancy (40%) in lesions deemed indeterminate at the time of biopsy. Thus, close follow-up or additional intervention should be pursued in such cases. Sonographic guidance resulted in a statistically significant decrease in the false-negative rate when compared with CT guidance; however, a history of malignancy, the biopsy site, the needle gauge and type, and the number of passes did not have a significant effect on the false-negative rate.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Biopsia con Aguja
/
Radiografía Intervencional
/
Ultrasonografía Intervencional
Tipo de estudio:
Diagnostic_studies
/
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Límite:
Humans
Idioma:
En
Revista:
AJR Am J Roentgenol
Año:
1999
Tipo del documento:
Article
País de afiliación:
Estados Unidos