Your browser doesn't support javascript.
loading
Semi-permeable surface analytical reversed-phase column for the improved trace analysis of acidic pesticides in water with coupled-column reversed-phase liquid chromatography with UV detection. Determination of bromoxynil and bentazone in surface water.
Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A.
Afiliación
  • Hogendoorn EA; Laboratory of Organic-Analytical Chemistry, National Institute of Public Health and the Environment (RIVM), Bilthoven, The Netherlands. elbert.hogendoorn@rivm.nl
J Chromatogr A ; 858(1): 45-54, 1999 Oct 08.
Article en En | MEDLINE | ID: mdl-10544890
ABSTRACT
The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Benzotiadiazinas / Cromatografía Líquida de Alta Presión / Herbicidas / Nitrilos Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr A Año: 1999 Tipo del documento: Article País de afiliación: Países Bajos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Contaminantes Químicos del Agua / Benzotiadiazinas / Cromatografía Líquida de Alta Presión / Herbicidas / Nitrilos Tipo de estudio: Diagnostic_studies Idioma: En Revista: J Chromatogr A Año: 1999 Tipo del documento: Article País de afiliación: Países Bajos