Your browser doesn't support javascript.
loading
Automated cardiac output measurements by ultrasound are inaccurate at high cardiac outputs.
Basdogan, F; Visser, W; Struijk, P C; Jansen, J R; Vletter, W B; Wladimiroff, J W; Lotgering, F K.
Afiliación
  • Basdogan F; Department of Obstetrics and Gynecology, Academic Hospital, Rotterdam, The Netherlands.
Ultrasound Obstet Gynecol ; 15(6): 508-12, 2000 Jun.
Article en En | MEDLINE | ID: mdl-11005119
OBJECTIVE: The sonographic technique of automated cardiac output measurement (ACM) is a promising new method to measure cardiac output and could be of use in a high-risk obstetric unit in the treatment of pre-eclamptic patients. The aim was to determine the accuracy of the ACM method. DESIGN: Comparative study of the sonographic technique of ACM versus cardiac output measured by thermodilution (TD). METHODS: The study included 39 intensive care patients, 21 men, 13 non-pregnant women and five severely pre-eclamptic pregnant patients, with a wide range of cardiac outputs, in whom TD catheters had been inserted for clinical reasons. Two separate experienced observers, blinded to the results obtained with the other method, performed four successive measurements in each patient with either the ACM or TD technique. The averaged cardiac output value per patient and method was used for comparison. RESULTS: Cardiac output was successfully measured with ACM and TD in 85 and 100% of patients, respectively. Mean cardiac output measured by ACM (6.77 +/- 1.90 L/min) was significantly lower than that measured by TD (9.12 +/- 3.06 L/min). Although cardiac output values obtained with ACM were significantly correlated with those measured by TD, the ACM values were consistently lower than TD values in the higher cardiac output range; the relationship was represented by ACM = 0.35 TD + 3.55 L/min (r = 0.57, P < 0.001). The (ACM - TD) difference increased significantly with cardiac output, through a difference in stroke volume, not in heart rate. CONCLUSION: The ACM is not an accurate tool to measure cardiac output in patients with a high cardiac output, including treated pre-eclamptic women.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gasto Cardíaco / Gasto Cardíaco Elevado / Ecocardiografía Doppler en Color Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Asunto de la revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Año: 2000 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Gasto Cardíaco / Gasto Cardíaco Elevado / Ecocardiografía Doppler en Color Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged / Pregnancy Idioma: En Revista: Ultrasound Obstet Gynecol Asunto de la revista: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Año: 2000 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Reino Unido