Your browser doesn't support javascript.
loading
Electrical storm presages nonsudden death: the antiarrhythmics versus implantable defibrillators (AVID) trial.
Exner, D V; Pinski, S L; Wyse, D G; Renfroe, E G; Follmann, D; Gold, M; Beckman, K J; Coromilas, J; Lancaster, S; Hallstrom, A P.
Afiliación
  • Exner DV; University of Calgary, Canada. exner@ucalgary.ca
Circulation ; 103(16): 2066-71, 2001 Apr 24.
Article en En | MEDLINE | ID: mdl-11319196
ABSTRACT

BACKGROUND:

Electrical storm, multiple temporally related episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF), is a frequent problem among recipients of implantable cardioverter defibrillators (ICDs). However, insufficient data exist regarding its prognostic significance. METHODS AND

RESULTS:

This analysis includes 457 patients who received an ICD in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial and who were followed for 31 +/- 13 months. Electrical storm was defined as > or = 3 separate episodes of VT/VF within 24 hours. Characteristics and survival of patients surviving electrical storm (n = 90), those with VT/VF unrelated to electrical storm (n = 184), and the remaining patients (n = 183) were compared. The 3 groups differed in terms of ejection fraction, index arrhythmia, revascularization status, and baseline medication use. Survival was evaluated using time-dependent Cox modeling. Electrical storm occurred 9.2 +/- 11.5 months after ICD implantation, and most episodes (86%) were due to VT. Electrical storm was a significant risk factor for subsequent death, independent of ejection fraction and other prognostic variables (relative risk [RR], 2.4; 95% confidence interval [CI], 1.3 to 4.2; P = 0.003), but VT/VF unrelated to electrical storm was not (RR, 1.0; 95% CI, 0.6 to 1.7; P = 0.9). The risk of death was greatest 3 months after electrical storm (RR, 5.4; 95% Cl, 2.4 to 12.3; P = 0.0001) and diminished beyond this time (RR, 1.9; 95% CI, 1.0 to 3.6; P=0.04).

CONCLUSIONS:

Electrical storm is an important, independent marker for subsequent death among ICD recipients, particularly in the first 3 months after its occurrence. However, the development of VT/VF unrelated to electrical storm does not seem to be associated with an increased risk of subsequent death.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Taquicardia Ventricular / Desfibriladores Implantables / Antiarrítmicos Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Circulation Año: 2001 Tipo del documento: Article País de afiliación: Canadá
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fibrilación Ventricular / Taquicardia Ventricular / Desfibriladores Implantables / Antiarrítmicos Tipo de estudio: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Circulation Año: 2001 Tipo del documento: Article País de afiliación: Canadá
...