Your browser doesn't support javascript.
loading
Fiducial point placement and the accuracy of point-based, rigid body registration.
West, J B; Fitzpatrick, J M; Toms, S A; Maurer, C R; Maciunas, R J.
Afiliación
  • West JB; Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee 37235, USA.
Neurosurgery ; 48(4): 810-6; discussion 816-7, 2001 Apr.
Article en En | MEDLINE | ID: mdl-11322441
OBJECTIVE: To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. METHODS: We consider two clinical situations: cranial neurosurgery and pedicle screw placement. For cranial neurosurgery, we apply theoretical results concerning TRE prediction, which we have previously derived and validated, to three hypothetical fiducial marker configurations. We illustrate the profile of expected TRE for each configuration. For pedicle screw placement, we apply the same theory to a common anatomic landmark configuration (tips of spinous and transverse processes) used for pedicle screw placement, and we estimate the error rate expected in placement of the screw. RESULTS: In the cranial neurosurgery example, we demonstrate that relatively small values of TRE may be achieved by using widely spread fiducial markers and/or placing the centroid of the markers near the target. We also demonstrate that near-collinear marker configurations far from the target may result in large TRE values. In the pedicle screw placement example, we demonstrate that the screw must be approximately 4 mm narrower than the pedicle in which it is implanted to minimize the chance of pedicle violation during placement. CONCLUSION: The placement of fiducial points is an important factor in minimizing the error rate for point-based, rigid registration. By using as many points as possible, avoiding near-collinear configurations, and ensuring that the centroid of the fiducial points is as near as possible to the target, TREs can be minimized.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Columna Vertebral / Fusión Vertebral / Procesamiento de Imagen Asistido por Computador / Interfaz Usuario-Computador / Encefalopatías / Imagen por Resonancia Magnética / Técnicas Estereotáxicas / Craneotomía Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Neurosurgery Año: 2001 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedades de la Columna Vertebral / Fusión Vertebral / Procesamiento de Imagen Asistido por Computador / Interfaz Usuario-Computador / Encefalopatías / Imagen por Resonancia Magnética / Técnicas Estereotáxicas / Craneotomía Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Neurosurgery Año: 2001 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos