Bronchial Rn dose survey for residences.
J Environ Radioact
; 54(2): 221-9, 2001.
Article
en En
| MEDLINE
| ID: mdl-11378916
The bronchial dosimeter for Rn progeny proposed by Yu and Guan in 1998 was employed to survey the bronchial dose from Rn progeny in 30 residences in Hong Kong. An average bronchial deposition fraction of Rn progeny was obtained as 0.0334, which gave an average dose conversion factor (DCF) of 8.5 mSv WLM-1. The mean values of potential alpha energy concentration (PAEC) deposited in the tracheobronchial region (PAECT-B), total PAEC in air (PAECT), annual effective dose (E), concentration of Rn gas (RC) and annual dose conversion factor (ADCF) for all the residential sites combined were 0.11 +/- 0.05, 3.1 +/- 1.4 mWL, 1.2 +/- 0.5 mSv yr-1, 23 +/- 10 Bq m-3 and 0.055 +/- 0.020 (mSv yr-1 per Bqm-3), respectively, with air-conditioned sites (AC sites) and non-AC sites having significantly different mean ADCF values. The indoor relative humidity affected PAECT and RC with high confidence levels (> 95%).
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Hijas del Radón
/
Contaminantes Radiactivos del Aire
Tipo de estudio:
Prognostic_studies
Límite:
Humans
País/Región como asunto:
Asia
Idioma:
En
Revista:
J Environ Radioact
Asunto de la revista:
SAUDE AMBIENTAL
Año:
2001
Tipo del documento:
Article
País de afiliación:
Hong Kong
Pais de publicación: