Relaxation effects of clustered particles.
J Magn Reson Imaging
; 14(1): 72-7, 2001 Jul.
Article
en En
| MEDLINE
| ID: mdl-11436217
Relations between spatial distribution of superparamagnetic iron oxide (SPIO) particles and the image contrast caused by SPIO were investigated. Actual clustering pattern of particles was measured in the liver and spleen of animals using intravital laser confocal microscopy. SPIO-doped phantoms with and without Sephadex beads were made to simulate these patterns, and relaxation parameters were measured using a 1.5-T clinical scanner. Finally, these results were compared to clinical image data using SPIO particulate agent. Intravital microscopy indicated that the clustering of latex beads was more predominant in hepatic Kupffer cells than in splenic macrophages (P < 0.001). Phantoms without Sephadex beads showed an approximately linear increase of 1/T1 (R1), 1/T2 (R2) and 1/T2* (R2*) values with increasing SPIO concentration. However, with Sephadex beads, R1 and R2 showed little change with increasing SPIO concentration, while R2* showed the same linear increase with SPIO. Also, the R2* values were higher with Sephadex beads. These results were consistent with the clinical imaging data, where signal reduction was significantly smaller in the spleen (-0.4% +/- 27.4%) than in the liver (50.4% +/- 16.8%, P < 0.00001) on T2*-weighted images, but the reduction in the spleen (47.2% +/- 16.1%) was equivalent to the liver (38.8% +/- 26.0%) on T2-weighted images.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Óxidos
/
Imagen por Resonancia Magnética
/
Aumento de la Imagen
/
Medios de Contraste
/
Hierro
Tipo de estudio:
Diagnostic_studies
Límite:
Aged
/
Animals
/
Humans
/
Male
Idioma:
En
Revista:
J Magn Reson Imaging
Asunto de la revista:
DIAGNOSTICO POR IMAGEM
Año:
2001
Tipo del documento:
Article
País de afiliación:
Japón
Pais de publicación:
Estados Unidos