The influence of tubule density and area of solid dentin on bond strength of two adhesive systems to dentin.
J Adhes Dent
; 3(4): 315-24, 2001.
Article
en En
| MEDLINE
| ID: mdl-11893047
PURPOSE: To determine the correlation between the tubule density (TD) and the area occupied by solid dentin (ASD) with the bond strength of one conventional and one self-etching adhesive system to dentin. MATERIALS AND METHODS: The crown of extracted human third molars was transversally sectioned with a diamond saw to expose either superficial, middle, or deep dentin. The three groups of dentin surfaces were randomly divided and bonded with either Clearfil Liner Bond 2V (LB) or Prime & Bond 2.1 (PB) adhesive systems according to manufacturer's directions. Resin composite buildup crowns (10.0 mm high) were incrementally constructed on the bonded surfaces and the teeth stored in water at 37 degrees C. After 24 h of storage, the teeth were vertically, serially sectioned in both x and y directions to obtain several bonded sticks of approximately 0.7 mm2 cross-sectional area. Each stick was tested in tension in a EMIC DL-500 tester at 0.5 mm/min until failure. After testing, the dentin side of the fractured specimen was gently abraded with a 1000-grit SiC paper, etched with 37% phosphoric acid for 15 s and allowed to air dry. SEM micrographs at 1000x and 4000x magnification were taken to permit calculation of the TD (number of tubules/mm2) and ASD (% of total area) at the site of fracture. Correlation between TD and ASD with the bond strength data was performed by linear regression. All statistical analysis was done with alpha = 0.05. RESULTS: Overall bond strength (MPa) for LB was 26.0 +/- 10.2, and 42.6 +/- 15.2 for PB. There was a significant direct relationship between bond strength and ASD for both materials (r2 = 0.20, p < 0.05 and r2 = 0.66, p < 0.01, respectively for LB and PB). PB bond strength dropped significantly as the TD increased (r2 = 0.63, p < 0.05), while LB was not sensitive to TD (r2 = 0.05, p > 0.05). Mean bond strength of PB was significantly higher than LB for both superficial and middle dentin (p < 0.05), while there was no significant difference for deep dentin (p > 0.05). CONCLUSION: Regional variations in TD and ASD may modify bond strength of both conventional and self-etching adhesive systems. Bonding sites with larger ASD seem to yield higher bond strengths regardless of the type of adhesive system used.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Circonio
/
Recubrimiento Dental Adhesivo
/
Recubrimientos Dentinarios
/
Dióxido de Silicio
/
Dentina
Tipo de estudio:
Clinical_trials
/
Prognostic_studies
Límite:
Humans
Idioma:
En
Revista:
J Adhes Dent
Asunto de la revista:
ODONTOLOGIA
Año:
2001
Tipo del documento:
Article
País de afiliación:
Brasil
Pais de publicación:
Alemania