Your browser doesn't support javascript.
loading
Inflammatory response of a new synthetic dialyzer membrane. A randomised cross-over comparison between polysulfone and helixone.
Stefoni, S; Colì, L; Cianciolo, G; Donati, G; Ruggeri, G; Ramazzotti, E; Pohlmeier, R; Lang, D.
Afiliación
  • Stefoni S; Nephrology Dialysis and Renal Transplantation Unit, Department of Clinical Medicine and Applied Biotechnology, S. Orsola University Hospital, Bologna, Italy.
Int J Artif Organs ; 26(1): 26-32, 2003 Jan.
Article en En | MEDLINE | ID: mdl-12602466
ABSTRACT
Hemodialysis patients suffer from chronic inflammation due to intradialytic contact of blood with artificial materials. The FX 60 dialyzer which belongs to the new FX-class series of dialyzers is composed of the new membrane Helixone. This membrane is derived from the original Fresenius Polysulfone membrane. The FX-class design is based on modified geometry of fibres and housing and has resulted in a new dialyzer with improved efficiency, safety and ease of handling compared to the F series (F 60S) dialyzer. The aim of the study was to investigate whether the biocompatibility pattern in terms of inflammatory parameters of the new type of polysulfone dialyzer has changed compared to the standard. A clinical in vivo study was conducted to compare the intradialytic inflammatory response of the two dialyzers, FX 60 and F 60S. Eight chronic dialysis patients were selected for the study mean age 65.5 +/- 15.5 years, mean time on dialysis 100 +/- 95 months. The randomized cross-over study involved a treatment period of 2 weeks (total 6 sessions), one week with each dialyzer, starting with one or the other according to the randomization scheme. Blood samples were taken at 0 (T0), 15, 60, and 240 minutes to evaluate white blood cell (WBC) count, complement factor C5a, leukocyte elastase, soluble intercellular adhesion molecule 1 (sICAM-1), platelet count, C-reactive protein (CRP). At 15 min, WBC count showed a comparably, low decrease for both dialyzers -7.6% for FX 60 versus -6.6% for F 60S, p=not significant (ns). At the same time the C5a concentration decreased from 15.0 +/- 7.5 ng/ml to 13.5 +/- 6.7 ng/ml (p=ns) for FX 60, and from 15.1 +/- 12.5 ng/ml to 14.9 +/- 25.0 ng/ml for F 60S (p=ns). The elastase concentration progressively increased over time with no statistical difference between the two dialyzers. The levels of sICAM-1, CRP, and platelet count were similar at each time point for both dialyzers, varying around the baseline values (p=ns). No significant difference emerged in terms of inflammatory response between the two dialyzers, hemo demonstrating that the biocompatibility of the F-series was maintained in the FX-class series of dialyzers and is independent of design factors.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Diálisis Renal / Inflamación / Membranas Artificiales Tipo de estudio: Clinical_trials / Etiology_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Artif Organs Año: 2003 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Diálisis Renal / Inflamación / Membranas Artificiales Tipo de estudio: Clinical_trials / Etiology_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int J Artif Organs Año: 2003 Tipo del documento: Article País de afiliación: Italia