Your browser doesn't support javascript.
loading
Transdiscal L5-S1 screws for the fixation of isthmic spondylolisthesis: a biomechanical evaluation.
Minamide, Akihito; Akamaru, Tomoyuki; Yoon, S Tim; Tamaki, Tetsuya; Rhee, John M; Hutton, William C.
Afiliación
  • Minamide A; Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia, USA.
J Spinal Disord Tech ; 16(2): 144-9, 2003 Apr.
Article en En | MEDLINE | ID: mdl-12679668
ABSTRACT
The current study is a biomechanical study using a cadaveric model of L5-S1 spondylolisthesis. The purpose of the current study was to compare, in a cadaveric model of simulated L5-S1 spondylolisthesis, the biomechanical stiffness of transdiscal fixation with traditional pedicle screw fixation, and transdiscal fixation with combined interbody/pedicle screw fixation. The surgical management of L5-S1 spondylolisthesis is a challenge because of the difficulties in achieving a reliable arthrodesis in the face of high mechanical forces. A method of lumbosacral fixation that has been used successfully in moderate grades of spondylolisthesis at our institution involves the use of transdiscal S1 pedicle screws. With this technique, S1 pedicle screws are placed through the S1 pedicle, through the superior endplate of S1, through the inferior endplate of L5, to terminate in the L5 body. Eighteen fresh human cadaveric (age 59-88 years) L5-S1 motion segments were obtained. The end of each intact motion segment was potted up to its midbody in a 10-cm-diameter polyvinylchloride end-cap using dental cement. The intact specimen was then biomechanically tested as follows 1) axial compression (500 N), 2) flexion (10 Nm), 3) extension (10 Nm), 4) right lateral bending (10 Nm), and 5) left lateral bending (10 Nm). Stiffness values were calculated from the load-deflection curves obtained. Spondylolisthesis was then simulated by displacing L5 on S1 (% slip average = 41.3%) after performing a radical L5-S1 discectomy, L5 laminectomy, and bilateral L5-S1 facetectomies. The 18 motion segments were divided into two groups. Group I (n = 10) was biomechanically tested (as above) after pedicle screw fixation and again after replacing the S1 pedicle screws with transdiscal screws. Group II (n = 8) was biomechanically tested (as above) after combined interbody/pedicle screw fixation and again after fixation with transdiscal screws. Load-deflection curves were obtained each time, and stiffness values were calculated from the curves. Transdiscal fixation was 1.6-1.8 times stiffer than pedicle screw fixation (p < 0.05) in all loading modes tested. There were no differences in stiffness between transdiscal fixation and combined interbody/pedicle screw fixation. In a cadaveric model of simulated L5-S1 spondylolisthesis, transdiscal L5-S1 fixation produced a 1.6-1.8 times stiffer construct than traditional pedicle screw fixation. Further, the stiffness of the transdiscal fixation was equal to that of a combined interbody/pedicle screw fixation.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tornillos Óseos / Espondilolistesis / Fijación Interna de Fracturas / Disco Intervertebral Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: J Spinal Disord Tech Asunto de la revista: ORTOPEDIA Año: 2003 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tornillos Óseos / Espondilolistesis / Fijación Interna de Fracturas / Disco Intervertebral Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Aged / Aged80 / Humans / Middle aged Idioma: En Revista: J Spinal Disord Tech Asunto de la revista: ORTOPEDIA Año: 2003 Tipo del documento: Article País de afiliación: Estados Unidos
...