Your browser doesn't support javascript.
loading
Correlation of interference screw insertion torque with depth of placement in the tibial tunnel using a quadrupled semitendinosus-gracilis graft in anterior cruciate ligament reconstruction.
Phillips, Barry B; Cain, E Lyle; Dlabach, Jeffrey A; Azar, Frederick M.
Afiliación
  • Phillips BB; Department of Orthopaedic Surgery, University of Tennessee-Campbell Clinic, Memphis, Tennessee, USA. lmjones@utmem.edu
Arthroscopy ; 20(10): 1026-9, 2004 Dec.
Article en En | MEDLINE | ID: mdl-15592230
ABSTRACT

PURPOSE:

To evaluate the insertion torque of a soft-tissue interference screw in relation to depth of insertion into the tibial tunnel when used for fixation of a quadrupled semitendinosus-gracilis autograft in anterior cruciate ligament reconstruction. TYPE OF STUDY Biomechanical cadaver study.

METHODS:

Ten quadrupled semitendinosus-gracilis grafts were harvested from fresh-frozen cadaver knees and fixed in donor proximal tibias using 10-mm bioabsorbable interference screws (Arthrex, Naples, FL). A cannulated torque screwdriver was used to measure screw insertion torque at 3 depths in the tibial tunnel the outer cortex (distal third), the articular surface (proximal third), and between these 2 points (middle third).

RESULTS:

The mean insertion torques for the distal third, middle third, and proximal third were 8.7, 4.7, and 4.3 in/lb, respectively. The insertion torque was significantly higher at the outer cortex (distal third) than the middle third and proximal third (joint line of the tibial tunnel) ( P < .05).

CONCLUSIONS:

Our results indicate a correlation between insertion torque and depth of placement of bioabsorbable interference screws used for fixation of a semitendinosus-gracilis graft. Lower insertion torque at the articular surface, resulting in lower peak load or pullout strength, may outweigh the proposed benefits of joint-line fixation of a semitendinosus-gracilis graft used for anterior cruciate ligament reconstruction. CLINICAL RELEVANCE Studies have suggested that anatomic proximal fixation of ACL grafts in the tibial tunnel produces stability similar to intact knees. The results of our study indicate that lower insertion torque at the articular surface results in lower peak load and pullout strength of the graft, which may outweigh the proposed benefits of joint-line fixation.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tendones / Tibia / Tornillos Óseos / Ligamento Cruzado Anterior Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Arthroscopy Asunto de la revista: ORTOPEDIA Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tendones / Tibia / Tornillos Óseos / Ligamento Cruzado Anterior Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Arthroscopy Asunto de la revista: ORTOPEDIA Año: 2004 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA