Your browser doesn't support javascript.
loading
Texture analysis of X-ray radiographs is correlated with bone histomorphometry.
Chappard, Daniel; Guggenbuhl, Pascal; Legrand, Erick; Baslé, Michel Félix; Audran, Maurice.
Afiliación
  • Chappard D; INSERM EMI 0335-LHEA-Rhumatologie, Faculté de Médecine, 49045 Angers, France. daniel.chappard@univ-angers.fr
J Bone Miner Metab ; 23(1): 24-9, 2005.
Article en En | MEDLINE | ID: mdl-15616890
ABSTRACT
Three-dimensional (3D) alteration of trabecular microarchitecture is a risk factor for vertebral fractures. Histomorphometry allows microarchitectural analysis of bone, but the necessity to perform a transiliac bone biopsy limits its use in large series of patients. X-Ray films are commonly used in routine practice and constitute a 2D projection of the trabecular architecture. In this study, blocks of trabecular dried bone were prepared from calf bone. They were selected from different parts of the femoral condyle to provide various patterns of trabecular disposition. All blocks (25 x 15 x 8 mm) were radiographed on a numeric X-ray system, with the same acquisition parameters. Texture analysis was carried out by several

methods:

(skeletonization, run lengths, and fractal techniques). Histological sections of the blocks were obtained and analyzed by 2D histomorphometric

methods:

trabecular bone volume (BV/TV), trabecular characteristics, and 2D descriptors of architecture (star volumes, strut analysis, fractal dimensions). Significant correlations were obtained for BV/TV with run length parameters measured on the X-ray image. The trabecular characteristics were found to be highly correlated with texture parameters describing the X-ray image (e.g., trabecular number [Tb.N]/axis, r = -0.82;/short run emphasis [SRE], r = -0.87; trabecular separation [Tb.Sp]/gray level nonuniformity [GLN], r = -0.82). Several histomorphometric parameters, independent of the "plate-and-rod" model, were also well correlated with texture descriptors. Although the relationships between the 2D and 3D trabecular architecture are not fully elucidated, the texture analysis of X-ray films might be a suitable approach to investigate the disorganization of bone in osteoporosis.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: J Bone Miner Metab Asunto de la revista: METABOLISMO Año: 2005 Tipo del documento: Article País de afiliación: Francia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Animals Idioma: En Revista: J Bone Miner Metab Asunto de la revista: METABOLISMO Año: 2005 Tipo del documento: Article País de afiliación: Francia