Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery.
Rosa, Nicola; Capasso, Luigi; Lanza, Michele; Iaccarino, Gennarfrancesco; Romano, Antonio.
Afiliación
  • Rosa N; Department of Ophthalmology, Second University of Naples, 80100 Naples, Italy. nicola.rosa@unina2.it
J Cataract Refract Surg ; 31(5): 1020-4, 2005 May.
Article en En | MEDLINE | ID: mdl-15975473
ABSTRACT

PURPOSE:

To test the reliability of a corneal radius correcting factor (R factor) in calculating intraocular lens (IOL) power in eyes that developed cataract after refractive surgery and compare it with the clinical history (CHM) and double-K (DKM) methods.

SETTING:

Department of Ophthalmology, Second University of Naples, Naples, Italy.

METHODS:

Nineteen eyes from the literature that underwent cataract extraction and IOL implantation after refractive surgery were used to compare actual postoperative and expected refractive errors utilizing the R factor, CHM, and DKM. Intraocular lens powers were calculated with 3 formulas SRK/T, Hoffer Q and Holladay 1. The differences were evaluated with the Wilcoxon test and Spearman correlation.

RESULTS:

With the R factor SRK/T and Holladay 1 formulas gave the best results; 16 (84.2%) and 17 (89.5%) eyes were within +/-2 diopters (D) of emmetropia. With CHM, the best results were obtained using the SRK/T and Holladay 1 formulas; with both formulas 12 (63.2%) eyes were within +/-2 D of emmetropia. With DKM, the best results were obtained using SRK/T and Holladay 1 formulas; with both formulas 10 eyes (52.63%) were in the range of +/-2 D from emmetropia.

CONCLUSIONS:

The R factor can be used with the SRK/T or Holladay 1 formula because this method seems comparable or superior to DKM and CHM.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Córnea / Procedimientos Quirúrgicos Refractivos / Óptica y Fotónica / Lentes Intraoculares / Modelos Teóricos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Córnea / Procedimientos Quirúrgicos Refractivos / Óptica y Fotónica / Lentes Intraoculares / Modelos Teóricos Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: J Cataract Refract Surg Asunto de la revista: OFTALMOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Italia