Evaluation of spiral computed tomography versus ventilation/perfusion scanning in patients clinically suspected of pulmonary embolism.
Katsouda, Emmanouela; Mystakidou, Kyriaki; Rapti, Aggeliki; Argentos, Stelios; Kelekis, Nikolaos L; Mastorakou, Renata; Anagnostopoulou, Ourania; Kelekis, Dimitrios A.
Afiliación
  • Katsouda E; Pain Relief and Palliative Care Unit, Department of Radiology, Areteion Hospital, School of Medicine, University of Athens, 27 Korinthias Str., 115 26 Athens, Greece.
In Vivo ; 19(5): 873-8, 2005.
Article en En | MEDLINE | ID: mdl-16097441
ABSTRACT

OBJECTIVE:

To prospectively evaluate the diagnostic accuracy of spiral computed tomography (CT) versus ventilation/perfusion (V/Q) scanning in the examination of patients clinically suspected of having pulmonary embolism (PE). PATIENTS AND

METHODS:

Sixty-three patients, presenting to the emergency department and departments of radiology and nuclear medicine of a large hospital, highly suspected of having PE, underwent sequential imaging testing with V/Q scanning and contrast-enhanced spiral CT, in addition to other clinical and laboratory tests.

RESULTS:

PE was diagnosed in 42 (66.7%) of the 63 patients. Thirty-nine of these 42 patients had positive findings in their CT scans, while 18 of the remaining 21 patients without PE had negative findings in their spiral CT [sensitivity, 92.9%, specificity, 85.7% Positive Predictive Value (PPV), 92.9%, Negative Predictive Value (NPV), 85.7%]. V/Q scans showed high-probability of PE in 24 of the 42 patients with PE and were negative in 9 of the remaining 21 patients without PE (sensitivity, 571%, specificity, 42.9%, PPV, 66.7%, NPV, 33.3%). There were statistically significant differences in specificity and sensitivity favoring spiral CT among men and women patients or patients > 50 years old. Fifty-four patients (85.7%) rated their satisfaction towards spiral CT as 'good' or 'very good', whereas the respective rate for V/Q scanning was only 14.3%.

CONCLUSION:

Spiral CT has an excellent sensitivity, specificity, PPV and NPV for the diagnosis of PE and it could be used as the first-line imaging modality in patients suspected of PE.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Pulmonar / Tomografía Computarizada por Rayos X / Tomografía Computarizada Espiral Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: In Vivo Asunto de la revista: NEOPLASIAS Año: 2005 Tipo del documento: Article País de afiliación: Grecia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Embolia Pulmonar / Tomografía Computarizada por Rayos X / Tomografía Computarizada Espiral Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: In Vivo Asunto de la revista: NEOPLASIAS Año: 2005 Tipo del documento: Article País de afiliación: Grecia