Long-term mortality in patients with pauses in ventricular electrical activity.
Saba, Magdi M; Donahue, Timothy P; Panotopoulos, Panagiotis T H; Ibrahim, Salma S; Abi-Samra, Freddy M.
Afiliación
  • Saba MM; Ochsner Clinic Foundation, New Orleans, LA 70121, USA.
Pacing Clin Electrophysiol ; 28(11): 1203-7, 2005 Nov.
Article en En | MEDLINE | ID: mdl-16359287
ABSTRACT

BACKGROUND:

The long-term significance of ventricular pauses of > or =3.0 seconds observed on Holter monitor is unclear, as previously conducted retrospective studies have been poorly controlled. We compared the prognosis of patients with pauses > or =3.0 seconds on Holter monitor with a well-matched control group without such pauses.

METHODS:

Scanning the Holter database at Ochsner Clinic (n = 11,730; January 1998 to June 2003) for pauses > or =3.0 seconds identified 70 patients (pause group). Of those, 29 (37.1%) received a permanent pacemaker (PPM group) and 41 (62.9%) did not (No-PPM group). For each No-PPM patient, two patients without pauses (<2.0 seconds) exactly matched for age, sex, ejection fraction (EF), rhythm, and duration of follow-up were randomly chosen from the Holter database (control group, n = 82) and survival of the two groups was compared.

RESULTS:

Mean age was 72.5 +/- 15.0 years, mean EF was 52.2 +/- 12.7%, and 68.3% were men. Mean follow-up was 2.2 years (0.5-4.5 years). There was no difference in survival between the No-PPM and the control groups (82.9% vs 84.1%, P = NS). Compared with the PPM group, pauses in the No-PPM group were more commonly asymptomatic, nocturnal, and due to sinus pauses or atrial fibrillation (AF) with slow ventricular response.

CONCLUSIONS:

Pauses in ventricular electrical activity > or =3 seconds on Holter monitor due to sinus pauses or AF with slow ventricular response are not predictive of heightened mortality.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Tasa de Supervivencia / Electrocardiografía Ambulatoria / Disfunción Ventricular Izquierda / Medición de Riesgo Tipo de estudio: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Pacing Clin Electrophysiol Año: 2005 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Tasa de Supervivencia / Electrocardiografía Ambulatoria / Disfunción Ventricular Izquierda / Medición de Riesgo Tipo de estudio: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: America do norte Idioma: En Revista: Pacing Clin Electrophysiol Año: 2005 Tipo del documento: Article País de afiliación: Estados Unidos